Skip to main content
Schneider Electric G12E4A32 — Miniature Circuit Breakers (MCB)

G12E4A32 GoPact MCCB 125 4P 32A TM-D 15kA 415V

MPNG12E4A32
Active

Schneider Electric GoPact MCCB 125, 4P, 32 A, TM-D trip unit, 15 kA at 415 V AC, screw terminals, IP20.

$109.20Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12E4A32 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12E4A32 — Ratings
ParameterValue
Rated current (In)32 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12E4A32 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12E4A32 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12E4A32 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12E4A32 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12E4A32 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity15 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12E4A32 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.8...1 x In
Trip unit protection functionsLI

Product details

The G12E4A32 is a GoPact MCCB 125 molded case circuit breaker, 4-pole, rated 32 A at 40 °C with a TM-D thermal-magnetic trip unit providing LI protection (overload and short-circuit). Rated operational voltage is 415 V AC at 50/60 Hz, with a breaking capacity of 15 kA at 380/415 V AC.

For a 32 A feeder, that covers most commercial and light industrial panelboards; if the available fault current at the panel exceeds 15 kA, you need an upstream current-limiting device or a higher-rated MCCB. 4 poles, 4D protected — all four poles have overcurrent protection, with the neutral pole protected at 1 x Ir. Neutral position is left, connection pitch 25 mm, screw terminals accept standard copper conductors. Electrical durability is 8000 cycles at rated current, mechanical durability 30000 cycles — adequate for a distribution breaker that sees infrequent switching; not intended for frequent motor starting duty. IP20 finger protection on the front, but the terminals are live when connected — install in a locked enclosure or panel with restricted access.

Fixed mounting on a backplate — not DIN-rail mountable. Dimensions: 130 mm height, 100 mm width, 60 mm depth. Mounting position can be horizontal, vertical, or flat on the back. Toggle control provides manual on/off and trip indication. Colour is grey (RAL 7035).

Frequently asked questions

What is the breaking capacity of G12E4A32?

15 kA at 380/415 V AC, which is the maximum fault current this 4-pole 32 A MCCB can safely interrupt.

Where can I buy G12E4A32?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What trip unit does G12E4A32 use?

A TM-D thermal-magnetic trip unit providing LI protection — thermal for overload, magnetic for short-circuit.

MPN
G12E4A32