Skip to main content
Schneider Electric G12E4F16 — Miniature Circuit Breakers (MCB)

Schneider GoPact G12E4F16 MCCB 4P 16A TM-D, 15 kA

MPNG12E4F16
Active

Schneider Electric GoPact MCCB 125, 4P, 16 A, TM-D thermal-magnetic trip unit, 15 kA at 415 V AC, screw terminals, grey (RAL 7035).

$104.82Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12E4F16 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12E4F16 — Ratings
ParameterValue
Rated current (In)16 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12E4F16 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12E4F16 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12E4F16 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12E4F16 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12E4F16 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity15 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12E4F16 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range1 x In
Trip unit protection functionsLI

Product details

The 4D protected poles and neutral protection set at 1 x Ir make it a straight fit for a 3-phase + N distribution circuit where you want full pole protection.

Mounts fixed to a backplate in either horizontal or vertical orientation — no DIN-rail clip here, so plan for screw-terminal landing on a panel or sub-panel. The 100 mm width, 130 mm height, and 60 mm depth with a 25 mm connection pitch fit standard MCCB cutouts. Front connections on both upside and downside keep wiring accessible for panel builders.

The GoPact MCCB range is Schneider's economy molded-case breaker line for distribution duty, built to EN/IEC 60947-1, -2, and Annex H. The 8000-cycle electrical endurance and 30000-cycle mechanical endurance are typical for this class — fine for infrequent switching in a distribution role, not for motor-starting duty.

Frequently asked questions

Where can I buy G12E4F16 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request for a firm price and lead time.

What compliance documentation does this brand provide for G12E4F16?

The breaker is certified to EN/IEC 60947-1, EN/IEC 60947-2, and EN/IEC 60947-2 Annex H. It is suitable for isolation per EN/IEC 60947-2. The manufacturer typically provides a Declaration of Conformity for CE marking and may supply RoHS/REACH declarations on request.

What is G12E4F16's listed colour?

Grey (RAL 7035).

What is G12E4F16's listed depth?

60 mm.

MPN
G12E4F16