Skip to main content
Schneider Electric G12E4F63 — Miniature Circuit Breakers (MCB)

G12E4F63 GoPact MCCB 125 63A 4P TM-D, 15 kA at 415 V

MPNG12E4F63
Active

Schneider Electric GoPact MCCB 125, G12E4F63, 4-pole molded case circuit breaker, 63 A at 40 °C, TM-D thermal-magnetic trip unit, 15 kA breaking capacity at 415 V AC, IP20, grey RAL 7035.

$106.64Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12E4F63 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12E4F63 — Ratings
ParameterValue
Rated current (In)63 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12E4F63 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12E4F63 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12E4F63 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12E4F63 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12E4F63 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity15 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12E4F63 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric G12E4F63 is a GoPact MCCB 125 molded case circuit breaker, 4-pole, rated 63 A at 40 °C with a TM-D thermal-magnetic trip unit. It breaks 15 kA at 415 V AC (50/60 Hz) per EN/IEC 60947-2, Category A — meaning it is not current-limiting and coordinates downstream with selective short-time delays. The 4D protected poles (neutral fully protected at 1 x Ir) suit it for distribution panels where a solid neutral is required.

Fixed backplate mount, 100 mm wide x 130 mm high x 60 mm deep. Screw terminals front-connected top and bottom on a 25 mm pitch — standard for panelboard busbar stabs. Neutral sits on the left; toggle control. Mount flat on the back, horizontal or vertical — no derating for orientation.

Electrical durability and isolation

Rated for 8000 electrical cycles at full load (415 V, In) and 30000 mechanical cycles — typical for a distribution-grade MCCB. Power dissipation per pole is 18.7 W at rated current — factor into enclosure thermal calculations for multi-pole installations.

Frequently asked questions

Who supplies G12E4F63 and how is it quoted for volume purchases?

The G12E4F63 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of G12E4F63?

63 A at 40 °C, 4-pole, TM-D thermal-magnetic trip, 15 kA breaking capacity at 415 V AC, 440 V insulation voltage, IP20, suitable for isolation.

What compliance documentation does this brand provide for G12E4F63?

The G12E4F63 is certified to EN/IEC 60947-1, EN/IEC 60947-2, and EN/IEC 60947-2 Annex H. Overvoltage category III, pollution degree 3.

MPN