Schneider Electric G12E4F32 — Miniature Circuit Breakers (MCB)

GoPact MCCB G12E4F32 32A 4P TM-D, 15 kA 415 V

MPNG12E4F32
Active

Schneider Electric GoPact MCCB 125, G12E4F32, 4P, TM-D thermal-magnetic trip, 32 A at 40 °C, 15 kA at 380/415 V AC, screw terminals, IP20, grey (RAL 7035).

$104.28Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12E4F32 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12E4F32 — Ratings
ParameterValue
Rated current (In)32 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12E4F32 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12E4F32 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12E4F32 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12E4F32 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12E4F32 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity15 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12E4F32 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric G12E4F32 is a GoPact MCCB 125 molded-case circuit breaker with a 4-pole (4P) configuration, a TM-D thermal-magnetic trip unit, and a rated current of 32 A at 40 °C. The LI protection curve (L for thermal overload, I for magnetic short-circuit) is the standard two-step response: the thermal element rides through harmless inrush, the magnetic element snaps open on a hard fault.

Connection pitch is 25 mm, which matches common bus-bar spacing.

Frequently asked questions

Who supplies G12E4F32 and how is it quoted for volume purchases?

We supply it through independent distribution. Submit an RFQ for current pricing and lead time — availability is confirmed at quote time.

What is the breaking capacity of G12E4F32?

The performance level is 15 kA at 380/415 V AC, which is the interrupting rating that governs fault-clearing capability.

What standards does G12E4F32 comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-2, and EN/IEC 60947-2 Annex H. It is also certified for isolation per EN/IEC 60947-2.

What is the closest alternative to G12E4F32 in this family?

Within the GoPact MCCB 125 range, any 4P TM-D unit with a different amp rating (e.g., 40 A or 50 A) shares the same frame, footprint, and trip-unit technology — the swap is just the thermal-magnetic calibration.