Skip to main content
Schneider Electric G12T4F32 — Miniature Circuit Breakers (MCB)

Schneider Electric G12T4F32 GoPact MCCB 125, 32 A, 10 kA, 4P

MPNG12T4F32
Active

Schneider Electric GoPact MCCB 125, 4P, 32 A, TM-D trip unit, 10 kA at 415 V AC, thermal-magnetic, IP20, grey (RAL 7035).

$104.28Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12T4F32 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12T4F32 — Ratings
ParameterValue
Rated current (In)32 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12T4F32 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12T4F32 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12T4F32 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12T4F32 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12T4F32 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity10 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity10 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12T4F32 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range1 x In
Trip unit protection functionsLI

Product details

The G12T4F32: Rated operational voltage is 415 V AC at 50/60 Hz, with a rated insulation voltage of 440 V AC — both conforming to EN/IEC 60947-2. This is the standard curve for general distribution — no electronic adjustability, but reliable and field-proven.

Fixed mounting on a backplate, with front-facing screw terminals for both line and load connections. Neutral is on the left, and the breaker can be mounted horizontally or vertically flat on the backplate — useful for tight enclosures where orientation is constrained.

The G12T4F32 carries IP20 finger protection (IEC 60529), suitable for installation inside a closed panel. Overvoltage category III qualifies it for fixed-installation distribution boards. Electrical durability is rated at 8000 cycles at 415 V at rated current; mechanical durability at 30,000 cycles.

Frequently asked questions

What are the key ratings of G12T4F32?

Rated current 32 A at 40 °C, breaking capacity 10 kA at 380/415 V AC, rated operational voltage 415 V AC 50/60 Hz, 4 poles, thermal-magnetic TM-D trip unit with LI protection.

What compliance documentation does G12T4F32 have?

Certified to EN/IEC 60947-1, EN/IEC 60947-2, and EN/IEC 60947-2 Annex H. Suitable for isolation per EN/IEC 60947-2. Pollution degree 3, overvoltage category III, IP20 protection.

Where can I buy G12T4F32?

The G12T4F32 is available to order through independent distribution. Submit an RFQ for current pricing and delivery commitment — availability is confirmed at quote time.

MPN