Schneider Electric GS2TB4 — Contactors

Schneider Electric GS2TB4 TeSys GS Switch-Disconnector-Fuse,

MPNGS2TB4
Obsolete

Schneider Electric TeSys GS switch-disconnector-fuse, GS2TB4, 4 poles, 800 A, BS fuse size C3, IEC 60947-3.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

GS2TB4 — Identification
ParameterValue
Product / component typeSwitch-disconnector-fuse
Series / rangeTeSys

Contacts & Poles

GS2TB4 — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

GS2TB4 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529 (with terminal cover)
Fire resistance850 °C fuse cover conforming to IEC 60695-2-1 960 °C body conforming to IEC 60695-2-1

Approvals

GS2TB4 — Approvals
ParameterValue
StandardsIEC 60947-3

Mechanical

GS2TB4 — Mechanical
ParameterValue
Width458 mm
Height300 mm
Depth250 mm

Product details

The Schneider Electric GS2TB4 is a TeSys GS switch-disconnector-fuse, a 4-pole unit rated for 800 A at 400 V AC-23B, making it suitable for switching motor and resistive loads in distribution panels where fused protection is required. It carries a rated operational power of 450 kW at 400 V and 400 kW at 690 V, with a breaking capacity of 6400 A at 400 V under AC-23B duty — meaning it can safely interrupt fault currents up to that level on motor circuits. The unit accepts BS-type fuses in size C3 and provides IP20 finger protection with the terminal cover fitted, so it belongs inside a locked enclosure or panel, not in a washdown area.

This part is officially obsolete per the manufacturer's lifecycle record. No direct successor order code is listed.

Mechanical durability is 8000 cycles, electrical durability is 1000 cycles at AC-23A and AC-23B — so this is a switch for infrequent operation, not a daily contactor replacement. The 12 kV rated impulse withstand voltage (Uimp) confirms it handles typical distribution transients. Mounting is plate-mount only, not DIN rail, and the power circuit terminals accept bars up to 63 mm² or ring lugs for 2 cables of 300 mm² or 185 mm². Tightening torque for the power circuit is 44 N·m — a substantial connection that needs the right tool.

Frequently asked questions

What standard does the GS2TB4 comply with?

It complies with IEC 60947-3, the standard for switches, disconnectors, switch-disconnectors and fuse-combination units.

MPN