Skip to main content
Schneider Electric GV2DM207E7 — Miniature Circuit Breakers (MCB)

Schneider TeSys GV2DM207E7 reversing motor starter, 1.6-2.5

MPNGV2DM207E7
Active

Schneider Electric TeSys Deca reversing motor starter, GV2DM207E7, 1.6-2.5 A thermal adjustment range, 48 V AC 50/60 Hz coil, 3-pole, AC-3 utilisation category.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2DM207E7 — Identification
ParameterValue
Product range (series)TeSys
Product/component typeMotor starter
GV2DM207E7 — Ratings
ParameterValue
Poles configuration3P
Utilisation categoryAC-3
GV2DM207E7 — Mechanical
ParameterValue
Width90 mm
Height176.4 mm
Depth99.6 mm
GV2DM207E7 — Other specifications
ParameterValue
Motor power0.75 kW at 400/415 V AC 50/60 Hz 0.75 kW at 440 V AC 50/60 Hz 1.1 kW at 440 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2DM
Device composition1 combination block GV2AF3 1 3-pole reversing contactor 1 motor circuit breaker type GV2ME
Motor starter typeReversing
Breaking capacityIq 50 kA at 400/415 V conforming to IEC 60947-4-1 Iq 50 kA at 440 V conforming to IEC 60947-4-1 Iq 50 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current33.5 A
Coil voltage48 V AC 50/60 Hz
Thermal protection adjustment range1.6...2.5 A

Product details

The Schneider Electric TeSys GV2DM207E7 is a reversing motor starter combination built for three-phase motor control in the 0.75 kW to 1.1 kW range at 400-500 V AC. It combines a GV2ME motor circuit breaker, a GV2AF3 combination block, and a 3-pole reversing contactor into a single pre-assembled unit, saving panel space and wiring time over a built-up solution. The thermal protection adjustment range of 1.6...2.5 A sets the overload trip point for the connected motor. The magnetic trip is fixed at 33.5 A, handling short-circuit events. Rated for AC-3 duty (motor starting and switching under load), this starter is sized for the motor power figures listed — 0.75 kW at 400/415 V and 1.1 kW at 500 V, for example. Breaking capacity is 50 kA at 400/415 V, 440 V, and 500 V per IEC 60947-4-1, with Type 1 coordination.

Panel integration and sourcing

The GV2DM207E7 mounts on a DIN rail. At 90 mm wide, 176.4 mm tall, and 99.6 mm deep, it fits a standard motor starter slot in a TeSys Deca lineup. The 48 V AC control coil matches common control transformer secondaries in industrial panels.

Frequently asked questions

What is the GV2DM207E7 used for?

It is a reversing motor starter used to start, stop, and reverse three-phase induction motors in the 0.75 to 1.1 kW range, with integrated thermal and magnetic protection.

Where can I buy the GV2DM207E7?

The GV2DM207E7 is available to order through independent distribution channels. Submit an RFQ for current pricing and availability.

What does the 50 kA breaking capacity mean?

It means the starter can safely interrupt a short-circuit fault up to 50,000 A at 400-500 V without damaging upstream equipment, per IEC 60947-4-1 Type 1 coordination.

MPN