Skip to main content
Schneider Electric GV2DM208F7 — Miniature Circuit Breakers (MCB)

Schneider GV2DM208F7 TeSys Deca Reversing Motor Starter, 2.5

MPNGV2DM208F7
Obsolete

Schneider Electric TeSys Deca reversing motor starter combination, GV2DM208F7, thermal protection adjustment 2.5-4 A, coil 110 V AC 50/60 Hz, 3-pole, AC-3 utilization category.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2DM208F7 — Identification
ParameterValue
Product range (series)TeSys TeSys Deca
Product/component typeMotor starter
GV2DM208F7 — Ratings
ParameterValue
Poles configuration3P
Utilisation categoryAC-3
GV2DM208F7 — Mechanical
ParameterValue
Width90 mm
Height176.4 mm
Depth99.6 mm
GV2DM208F7 — Other specifications
ParameterValue
Motor power1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.5 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2DM
Device composition1 combination block GV2AF3 1 3-pole reversing contactor 1 motor circuit breaker type GV2ME
Motor starter typeReversing
Breaking capacityIq 50 kA at 400/415 V conforming to IEC 60947-4-1 Iq 50 kA at 440 V conforming to IEC 60947-4-1 Iq 50 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current51 A
Coil voltage110 V AC 50/60 Hz
Thermal protection adjustment range2.5...4 A

Product details

The Schneider GV2DM208F7 is a reversing motor starter combination from the TeSys Deca range — a factory-assembled block that pairs a GV2ME motor circuit breaker with a 3-pole reversing contactor on a GV2AF3 combination base. It provides coordinated motor starting, stopping, and reversing in a single DIN-rail-mounted package. Thermal protection adjusts from 2.5 to 4 A, and the magnetic trip is fixed at 51 A. Rated for AC-3 duty (squirrel-cage motor switching), the combination delivers a breaking capacity of 50 kA at 400/415 V, 440 V, and 500 V per IEC 60947-4-1 — sufficient for high-fault-capacity industrial panels without upstream fusing in many configurations.

The 2.5–4 A thermal adjustment range covers small motor loads — think fractional-horsepower conveyors, fan drives, or pump starters in the 1.1 kW to 2.5 kW band at 400–500 V AC. The 51 A magnetic trip clears short-circuit faults fast, but it is not adjustable; verify that the motor's locked-rotor current stays below that threshold to avoid nuisance trips. Type 1 coordination means the starter itself may be damaged during a short-circuit fault below 50 kA, but the upstream protection device remains undamaged and the installation stays safe. For applications requiring Type 2 coordination (starter remains usable after a fault), a different combination or additional upstream fusing is needed.

Frequently asked questions

Where can I buy GV2DM208F7?

We source the GV2DM208F7 to order against an RFQ through independent distribution channels. Submit a request for current pricing and availability — we confirm both at quote time.

What is the closest alternative to GV2DM208F7 in the TeSys family?

No official successor is listed. A functionally similar reversing starter from the current TeSys Deca or TeSys Island range would need to match the 2.5–4 A thermal range, 110 V AC coil, and 3-pole reversing configuration — but pin-to-pin compatibility and mounting footprint should be verified against the panel layout before substitution.

What compliance documentation does Schneider provide for GV2DM208F7?

The GV2DM208F7 carries IEC 60947-4-1 certification for breaking capacity. Standard Schneider documentation for this series includes a CE declaration of conformity and RoHS/REACH compliance statements — these are available on request with the RFQ.

MPN
GV2DM208F7