Skip to main content
Schneider Electric GV2DM221F7 — Miniature Circuit Breakers (MCB)

Schneider GV2DM221F7 TeSys Deca Reversing Motor Starter, 17-

MPNGV2DM221F7
Obsolete

Schneider Electric TeSys Deca reversing motor starter combination, GV2DM221F7, 17…23 A thermal protection range, 110 V AC 50/60 Hz control coil, 3-pole, Type 1 coordination.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2DM221F7 — Identification
ParameterValue
Product range (series)TeSys TeSys Deca
Product/component typeMotor starter
GV2DM221F7 — Ratings
ParameterValue
Poles configuration3P
Utilisation categoryAC-3
GV2DM221F7 — Mechanical
ParameterValue
Width90 mm
Height186.8 mm
Depth105.9 mm
GV2DM221F7 — Other specifications
ParameterValue
Motor power9 kW at 400/415 V AC 50/60 Hz 11 kW at 440 V AC 50/60 Hz 11 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2DM
Device composition1 3-pole reversing contactor 1 combination block GV2AF3 1 motor circuit breaker type GV2ME
Motor starter typeReversing
Breaking capacityIq 15 kA at 400/415 V conforming to IEC 60947-4-1 Iq 6 kA at 440 V conforming to IEC 60947-4-1 Iq 4 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current327 A
Coil voltage110 V AC 50/60 Hz
Thermal protection adjustment range17...23 A

Product details

The Schneider GV2DM221F7 is a reversing motor starter combination from the TeSys Deca family — a factory-assembled unit that bundles a 3-pole reversing contactor, a GV2AF3 combination block, and a GV2ME motor circuit breaker into one panel-ready package. Its thermal protection adjustment range of 17…23 A sets the overload trip point for the motor in the circuit, while the fixed magnetic trip of 327 A handles short-circuit protection upstream of the overload curve. Rated for AC-3 utilization (switching squirrel-cage motors), the unit delivers 9 kW at 400/415 V and 11 kW at both 440 V and 500 V — so the same starter covers 400 V to 500 V networks without a frame size change.

Rated breaking capacity reaches 15 kA at 400/415 V, 6 kA at 440 V, and 4 kA at 500 V — the 15 kA figure at the common 400 V level gives solid headroom for most distribution panels with typical transformer impedances.

The unit measures 90 mm wide, 186.8 mm tall, and 105.9 mm deep — a compact footprint for a reversing starter that includes both the contactor and breaker in one assembly. Width of 90 mm matches the standard TeSys Deca mounting grid; plan for the depth when routing control wiring behind the DIN rail or against a back panel.

Frequently asked questions

Where can I buy GV2DM221F7?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

What is the thermal protection range of GV2DM221F7?

The thermal overload adjustment range is 17…23 A, set via the dial on the integrated GV2ME breaker.

What control voltage does GV2DM221F7 use?

The control coil is rated 110 V AC at 50/60 Hz.

What compliance documentation is available for GV2DM221F7?

The part carries IEC 60947-4-1 certification for breaking capacity and coordination. Original Schneider documentation (datasheet, declaration of conformity) is typically available from the manufacturer's archive for this TeSys Deca series.

MPN
GV2DM221F7