Schneider Electric TeSys Deca reversing motor starter combination, GV2DM222F7, 20-25 A thermal protection, 110 V AC 50/60 Hz coil, 3-pole, Type 1 coordination.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2DM222F7 — Mechanical & Connection
ParameterValue
Width90 mm
Height186.8 mm
Depth105.9 mm
GV2DM222F7 — Other specifications
ParameterValue
Motor power11 kW at 400/415 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz
Range of productTeSys TeSys Deca
Coordination typeType 1
Device short nameGV2DM
Poles description3P
Device composition1 combination block GV2AF3 1 motor circuit breaker type GV2ME 1 3-pole reversing contactor
Motor starter typeReversing
Utilisation categoryAC-3
Breaking capacityIq 15 kA at 400/415 V conforming to IEC 60947-4-1 Iq 6 kA at 440 V conforming to IEC 60947-4-1 Iq 4 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current327 A
Product or component typeMotor starter
Coil voltage110 V AC 50/60 Hz
Thermal protection adjustment range20...25 A

Product details

The GV2DM222F7 is a reversing motor starter combination from the TeSys Deca range — a factory-assembled block that pairs a GV2ME motor circuit breaker with a 3-pole reversing contactor on a GV2AF3 combination base. Its thermal protection adjustment range of 20 to 25 A and control circuit voltage of 110 V AC 50/60 Hz define the motor current and coil supply it expects. The magnetic trip is fixed at 327 A, which clears short-circuit faults before the contactor welds shut, provided the upstream protection is coordinated to Type 1.

The 20-25 A thermal adjustment range sets the motor full-load current it can protect — a 25 A setting, for example, suits an 11 kW motor at 400/415 V (AC-3 duty) or a 15 kW motor at 500 V. The 110 V AC 50/60 Hz coil means the control transformer or PLC output driving it must supply exactly that voltage; a 24 VDC or 230 VAC control circuit will not pick this contactor. Type 1 coordination means the starter may be damaged after a fault and require replacement of the contactor; if the process cannot tolerate that downtime, a Type 2 coordination design would be needed.

Physical integration

The assembly measures 90 mm wide by 186.8 mm high by 105.9 mm deep. The depth of 105.9 mm means the gland plate and door clearance must accommodate that projection plus wiring space — a shallow enclosure may not close cleanly with the reversing contactor's coil terminals and power cables dressed.

Frequently asked questions

How do I get current pricing and availability for GV2DM222F7?

The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What is the thermal protection adjustment range on GV2DM222F7?

The thermal protection adjustment range is 20 to 25 A, which sets the motor full-load current the starter can protect.

What control circuit voltage does GV2DM222F7 require?

The control circuit voltage is 110 V AC 50/60 Hz — the contactor coil is wound for that supply.

What is the rated breaking capacity of GV2DM222F7?

The rated breaking capacity is 15 kA at 400/415 V, 6 kA at 440 V, and 4 kA at 500 V, all conforming to IEC 60947-4-1.