Skip to main content
Schneider Electric GV2DP204F7 — Miniature Circuit Breakers (MCB)

TeSys Deca GV2DP204F7 Reversing Motor Starter, 0.4-0.63A, 11

MPNGV2DP204F7
Obsolete

Schneider Electric TeSys Deca reversing motor starter, GV2DP204F7, 0.4 to 0.63 A thermal adjustment, 110 V AC 50/60 Hz coil, 130 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2DP204F7 — Identification
ParameterValue
Product range (series)TeSys TeSys Deca
Product/component typeMotor starter
GV2DP204F7 — Ratings
ParameterValue
Poles configuration3P
Utilisation categoryAC-3
GV2DP204F7 — Mechanical
ParameterValue
Width90 mm
Height176.4 mm
Depth105.6 mm
GV2DP204F7 — Other specifications
ParameterValue
Motor power0.12 kW at 400/415 V AC 50/60 Hz 0.18 kW at 400/415 V AC 50/60 Hz 0.18 kW at 440 V AC 50/60 Hz
Coordination typeType 2
Device short nameGV2DP
Device composition1 combination block GV2AF3 1 3-pole reversing contactor 1 motor circuit breaker type GV2P
Motor starter typeReversing
Breaking capacityIq 130 kA at 400/415 V conforming to IEC 60947-4-1 Iq 130 kA at 440 V conforming to IEC 60947-4-1 Iq 130 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current8 A
Coil voltage110 V AC 50/60 Hz
Thermal protection adjustment range0.4...0.63 A

Product details

The GV2DP204F7 is a reversing motor starter from the TeSys Deca range — a factory-assembled combination of a GV2P motor circuit breaker and a 3-pole reversing contactor on a GV2AF3 mounting base. It is rated for AC-3 duty (squirrel-cage motor switching) with a thermal protection adjustment range of 0.4 to 0.63 A, making it suitable for small motors in the 0.12 to 0.18 kW range at 400/415 V or 440 V AC. The control circuit runs on 110 V AC 50/60 Hz, and the unit delivers a rated breaking capacity of 130 kA at 400/415 V, 440 V, and 500 V per IEC 60947-4-1 — meaning it can safely interrupt fault currents up to that level without upstream damage, provided the installation is coordinated as Type 2.

The 0.4 to 0.63 A thermal adjustment range sets the motor full-load current the overload relay protects — set the dial to match the motor nameplate FLA. The magnetic trip is fixed at 8 A, so it clears short-circuits without nuisance tripping on motor inrush. The 130 kA breaking capacity at 400/415 V means this starter can be installed on a high-fault-capacity supply (typical of industrial distribution) without requiring a separate upstream current-limiting device, as long as the coordination study confirms Type 2. Dimensions are 90 mm wide, 176.4 mm high, and 105.6 mm deep — a standard TeSys Deca footprint that fits DIN-rail or panel-mount enclosures. The reversing contactor pair occupies the same width as a non-reversing starter, so panel layout stays consistent when swapping between forward-only and reversing configurations.

Frequently asked questions

Who supplies GV2DP204F7 and how is it quoted for volume purchases?

We source this obsolete part through our independent distribution network. Availability and current pricing are confirmed at quote time against an RFQ — no stock figures or price lists apply to a discontinued line.

What compliance documentation does this brand provide for GV2DP204F7?

The part carries IEC 60947-4-1 conformity for breaking capacity and coordination. RoHS, REACH, and UL documentation would have been issued at the time of manufacture; for an obsolete part, archived certificates may be available from the manufacturer's documentation portal.

MPN
GV2DP204F7