Dimensions are 90 mm wide, 186.8 mm high, and 111.9 mm deep. That 90 mm width is three 18 mm modules wide — standard for a reversing starter with a breaker and contactor side-by-side. Make sure your enclosure depth clears 111.9 mm plus wiring space behind the rail. The control circuit is 110 V AC 50/60 Hz — not a DC coil, not a 24 V coil. If your panel runs a different control voltage, you'll need an interposing relay or a different starter variant. The coil draw isn't listed here, but for a reversing contactor pair expect it to pull around the same VA as two standard contactors of this frame size.
Schneider GV2DP214F7 TeSys Deca Reversing Motor Starter, 6-1
Schneider Electric TeSys Deca reversing motor starter combination, GV2DP214F7, 6-10 A thermal protection, 110 V AC 50/60 Hz coil, 3-pole, Type 2 coordination.
Specifications
| Parameter | Value |
|---|---|
| Product range (series) | TeSys TeSys Deca |
| Product/component type | Motor starter |
| Parameter | Value |
|---|---|
| Poles configuration | 3P |
| Utilisation category | AC-3 |
| Parameter | Value |
|---|---|
| Width | 90 mm |
| Height | 186.8 mm |
| Depth | 111.9 mm |
| Parameter | Value |
|---|---|
| Motor power | 3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz |
| Coordination type | Type 2 |
| Device short name | GV2DP |
| Device composition | 1 3-pole reversing contactor 1 combination block GV2AF3 1 motor circuit breaker type GV2P |
| Motor starter type | Reversing |
| Breaking capacity | Iq 130 kA at 400/415 V conforming to IEC 60947-4-1 Iq 130 kA at 440 V conforming to IEC 60947-4-1 Iq 50 kA at 500 V conforming to IEC 60947-4-1 |
| Magnetic tripping current | 138 A |
| Coil voltage | 110 V AC 50/60 Hz |
| Thermal protection adjustment range | 6...10 A |
Product details
Frequently asked questions
What is the thermal protection adjustment range on GV2DP214F7?
The thermal protection adjustment range is 6...10 A. Set it to match the full-load current of the motor you're protecting.
What does Type 2 coordination mean for this motor starter?
Type 2 coordination per IEC 60947-4-1 means that after a short-circuit fault within the rated breaking capacity, the contactor and overload relay remain usable — no contact welding, no parts replacement needed. That keeps downtime and spare-part costs low.
Where can I buy GV2DP214F7?
This obsolete part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.