Skip to main content
Schneider Electric GV2DP206B7 — Miniature Circuit Breakers (MCB)

Schneider GV2DP206B7 TeSys Deca Reversing Motor Starter, 1-1

MPNGV2DP206B7
Obsolete

Schneider Electric TeSys Deca reversing motor starter, GV2DP206B7, 1-1.6 A thermal protection, 24 V AC 50/60 Hz coil, 130 kA breaking capacity, 3-pole, AC-3 utilization.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2DP206B7 — Identification
ParameterValue
Product range (series)TeSys TeSys Deca
Product/component typeMotor starter
GV2DP206B7 — Ratings
ParameterValue
Poles configuration3P
Utilisation categoryAC-3
GV2DP206B7 — Mechanical
ParameterValue
Width90 mm
Height176.4 mm
Depth105.6 mm
GV2DP206B7 — Other specifications
ParameterValue
Motor power0.55 kW at 400/415 V AC 50/60 Hz 0.55 kW at 440 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz
Coordination typeType 2
Device short nameGV2DP
Device composition1 motor circuit breaker type GV2P 1 3-pole reversing contactor 1 combination block GV2AF3
Motor starter typeReversing
Breaking capacityIq 130 kA at 400/415 V conforming to IEC 60947-4-1 Iq 130 kA at 440 V conforming to IEC 60947-4-1 Iq 130 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current22.5 A
Coil voltage24 V AC 50/60 Hz
Thermal protection adjustment range1...1.6 A

Product details

The Schneider GV2DP206B7 is a reversing motor starter from the TeSys Deca range — a factory-assembled combination of a GV2P motor circuit breaker, a 3-pole reversing contactor, and a GV2AF3 mechanical interlock block. It's a single-unit reversing starter that handles the forward-reverse switching and overload protection for a small motor in one package. Rated for AC-3 duty (motor switching), the thermal protection adjustment range is 1 to 1.6 A, so it's sized for a motor drawing roughly 0.55 kW at 400/415 V or 0.75 kW at 500 V. The magnetic trip is fixed at 22.5 A — that's the instantaneous short-circuit release, not adjustable. Breaking capacity is 130 kA at 400/415 V, 440 V, and 500 V per IEC 60947-4-1. That's a Type 2 coordination rating — meaning the starter survives a fault at those levels without damage to the contactor or breaker, just a blown fuse upstream if used in a fused configuration.

Sourcing and fit for your panel

Panel cutout dimensions are 90 mm wide by 176.4 mm high, with a depth of 105.6 mm — that's the full depth including the contactor and interlock block. Compliance documentation for this series includes IEC 60947-4-1 (the standard for motor starters and contactors) and the usual CE marking for European markets. RoHS and REACH declarations are available from Schneider's legacy documentation archives.

Frequently asked questions

Where can I buy GV2DP206B7 and how do I get a price?

We source the GV2DP206B7 through our independent distribution network against an RFQ. Send us your quantity and target price — availability and current pricing are confirmed at quote time. No stock is held on the shelf for this obsolete code.

What is the closest alternative to GV2DP206B7 in the TeSys range?

There is no single order-code replacement. The modern equivalent is a field-assembled TeSys Deca reversing starter: a GV2P motor circuit breaker (choose the thermal range you need, e.g. GV2P07 for 1-1.6A) plus an LC2D reversing contactor with the same coil voltage, plus a GV2AF3 mechanical interlock. The footprint and wiring pattern are similar, but the BOM changes.

What compliance documentation does Schneider provide for GV2DP206B7?

The GV2DP series carries IEC 60947-4-1 certification for motor starters and CE marking. RoHS and REACH compliance declarations are available from Schneider's legacy documentation; we can provide them with the order.

MPN
GV2DP206B7