Skip to main content
Schneider Electric GV2DP208B7 — Miniature Circuit Breakers (MCB)

TeSys GV2DP208B7 Reversing Motor Starter, 2.5-4A, 24VAC

MPNGV2DP208B7
Obsolete

Schneider Electric TeSys Deca reversing motor starter, GV2DP208B7, 2.5 to 4 A thermal protection, 24 V AC 50/60 Hz coil, 3-pole, AC-3 utilisation category.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2DP208B7 — Identification
ParameterValue
Product range (series)TeSys TeSys Deca
Product/component typeMotor starter
GV2DP208B7 — Ratings
ParameterValue
Poles configuration3P
Utilisation categoryAC-3
GV2DP208B7 — Mechanical
ParameterValue
Width90 mm
Height176.4 mm
Depth105.6 mm
GV2DP208B7 — Other specifications
ParameterValue
Motor power1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.5 kW at 500 V AC 50/60 Hz
Coordination typeType 2
Device short nameGV2DP
Device composition1 motor circuit breaker type GV2P 1 combination block GV2AF3 1 3-pole reversing contactor
Motor starter typeReversing
Breaking capacityIq 130 kA at 400/415 V conforming to IEC 60947-4-1 Iq 130 kA at 440 V conforming to IEC 60947-4-1 Iq 130 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current51 A
Coil voltage24 V AC 50/60 Hz
Thermal protection adjustment range2.5...4 A

Product details

It is rated for AC-3 duty (squirrel-cage motor switching) and covers motor loads from 1.1 kW at 400/415 V up to 2.5 kW at 500 V, depending on the supply voltage. The thermal protection adjustment range is 2.5 to 4 A, with a fixed magnetic trip threshold of 51 A for short-circuit protection. The breaking capacity reaches 130 kA at 400/415 V, 440 V, and 500 V per IEC 60947-4-1 — high enough for most industrial distribution panels without upstream current-limiting fuses. The unit is Type 2 coordinated, meaning the contactor remains serviceable after a fault at the rated breaking capacity — no welding or damage that requires replacement.

If a direct drop-in replacement exists within the current TeSys range, it would need to be verified against the original panel layout and coordination study — the 2.5–4 A thermal band and 24 VAC coil are the critical fit parameters.

The GV2DP208B7 occupies a 90 mm wide footprint on the DIN rail, with a height of 176.4 mm and depth of 105.6 mm. The reversing contactor pair and the circuit breaker share the same mounting base, so the assembly arrives pre-wired internally — no need to build the reversing interlock from separate contactors. The 24 VAC coil draws from the control transformer; verify that the transformer VA rating covers the inrush of both contactors when the reversing direction is switched. The unit is designed for panel mounting with screw-clamp terminals on the power and control sides.

Frequently asked questions

What is the thermal protection range of GV2DP208B7?

The thermal protection adjustment range is 2.5 to 4 A, with a fixed magnetic trip at 51 A. This covers small motor loads up to about 2.5 kW depending on the supply voltage.

What is the breaking capacity of this motor starter?

The rated breaking capacity is 130 kA at 400/415 V, 440 V, and 500 V, per IEC 60947-4-1. This is a high-fault rating suitable for industrial panels without additional upstream current limiting.

Who supplies GV2DP208B7 and how is it quoted for volume purchases?

Since the part is obsolete, it is sourced through independent distribution and surplus channels. Submit an RFQ with your target quantity; availability and pricing are confirmed at quote time through our network of suppliers.

What are the physical dimensions of GV2DP208B7?

Width is 90 mm, height is 176.4 mm, and depth is 105.6 mm. It mounts on a standard DIN rail.

MPN