Schneider Electric GV2ME02A — Molded Case Circuit Breakers (MCCB)

Schneider Electric GV2ME02A TeSys GV2 Motor Circuit Breaker,

MPNGV2ME02A
Active

Schneider Electric TeSys GV2 motor circuit breaker, 3-pole, 0.25 A rated current, thermal-magnetic trip, 100 kA breaking capacity at 400 V AC, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME02A — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection
GV2ME02A — Mechanical
ParameterValue
Height101 mm
Width45 mm
Depth78.5 mm
GV2ME02A — Electrical
ParameterValue
[In] rated current0.25 A
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2ME02A — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2ME
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2

Product details

The Schneider Electric GV2ME02A is a TeSys GV2 motor circuit breaker — a 3-pole thermal-magnetic device sized for protecting a 0.06 kW motor at 400/415 V AC. The 0.25 A rated current (In) with a thermal adjustment range of 0.16...0.25 A means the trip threshold is set at the factory but can be dialed down to match the motor's full-load amps. This is the number that decides fit: if your motor draws 0.2 A FLA, this breaker covers it; if it draws 0.3 A, you need the next step up. The magnetic trip is fixed at 3.08 A — about 12× In — so it handles starting inrush without nuisance tripping on small motors. Phase-failure sensitivity is built in per IEC 60947-4-1, so a lost phase on the line side trips the breaker rather than cooking the motor.

Breaking capacity — what 100 kA means in practice

Rated 100 kA Icu at 400/415 V AC (and at every voltage from 230 V up to 690 V), this breaker clears the maximum prospective fault current available at a typical industrial panel's main bus without needing an upstream current-limiting fuse. For a 0.25 A breaker that's extreme headroom — but it means the part installs into a high-fault-capacity distribution board without a coordination study for the branch circuit. The standard behind it is IEC 60947-2 for circuit breakers and IEC 60947-4-1 for motor starters.

Clips onto 35 mm symmetrical DIN rail (standard for control panels) or screws to a panel with an adaptor plate. Dimensions: 45 mm wide, 101 mm high, 78.5 mm deep — fits a standard 45 mm modular device footprint. The IP20 front face means it's touch-safe for the panel builder but not washdown-rated; keep it inside the enclosure. Terminals accept 0.5...2.5 mm² solid or 0.5...4 mm² flexible (without ferrule), two cables per terminal — useful for daisy-chaining the control circuit.

Approvals and compliance documentation

Carries UL 60947-4-1, CSA C22.2 No 60947-4-1, and EN/IEC 60947-2 and -4-1 — accepted in North American and European panels without additional evaluation. Also certified for IEC/EN 60335-1 Clause 30.2 (glow-wire for household appliances) and IEC/EN 60335-2-40 Annex JJ (heat pumps and air conditioners). Fire resistance tested to 960 °C per IEC 60695-2-11. Climatic withstand per IACS (marine environment).

Frequently asked questions

What are the key ratings that determine fit?

The two numbers that decide fit are the 0.25 A rated current (In) and the thermal adjustment range of 0.16...0.25 A. If your motor's full-load amps fall inside that window, this breaker covers it. The magnetic trip at 3.08 A handles inrush on small motors without nuisance tripping.

What compliance documentation is available for the GV2ME02A?

The part is certified to UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-2, and EN/IEC 60947-4-1. It also meets IEC/EN 60335-1 Clause 30.2 and IEC/EN 60335-2-40 Annex JJ for appliance applications. Fire resistance is tested to 960 °C per IEC 60695-2-11.

What is the physical size for panel layout?

45 mm wide, 101 mm high, 78.5 mm deep. Mounts on 35 mm DIN rail or screws to a panel with an adaptor plate. The IP20 front face means it is touch-safe inside an enclosure.