Schneider GV2ME02TQ TeSys GV2 Motor Circuit Breaker, 0.25 A

MPNGV2ME02TQ
Obsolete

Schneider Electric TeSys Deca GV2ME02TQ motor circuit breaker, 0.25 A, thermal-magnetic, 3-pole, 100 kA breaking capacity, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME02TQ — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection
GV2ME02TQ — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth78.5 mm
GV2ME02TQ — Electrical
ParameterValue
[In] rated current0.25 A
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2ME02TQ — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2ME
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2

Product details

The Schneider Electric GV2ME02TQ is a TeSys GV2 motor circuit breaker — a thermal-magnetic device sized for protecting a 0.06 kW motor at 400/415 V AC 50/60 Hz. The phase-failure sensitivity per IEC 60947-4-1 means it will trip if one phase drops out — protecting the motor from single-phasing. Mechanical durability is 100,000 cycles, which is typical for a manual motor starter in a panel that sees occasional switching.

The 45 mm width means it takes up a single modular space on the rail — standard for a 3-pole motor-protective device. Screw-clamp terminals accept up to 2 x 6 mm² solid or 2 x 4 mm² flexible with ferrule; torque to 1.7 N·m. Mount it horizontally or vertically; the thermal trip calibration holds either way. The IK04 impact rating handles accidental tool bumps during commissioning. Operating altitude is limited to 2000 m without derating.

Carries dual certification to IEC/EN 60947-2 (for circuit-breaker function) and IEC/EN 60947-4-1 (for motor-starter coordination), plus UL 60947-4-1 and CSA C22.2 No 60947-4-1. Also listed for use in IEC/EN 60335 appliance circuits per Annex JJ and Clause 30.2. Fire resistance tested to 960 °C per IEC 60695-2-11. Climatic withstand per IACS covers marine and humid environments.

Frequently asked questions

What are the key ratings for the GV2ME02TQ?

Rated current (In) is 0.25 A. Magnetic trip threshold is 3.08 A. Breaking capacity is 100 kA Icu at 400/415 V AC. Motor power rating is 0.06 kW at 400/415 V AC 50/60 Hz. Rated insulation voltage (Ui) and operational voltage (Ue) are both 690 V AC.

What standards does the GV2ME02TQ comply with?

It complies with IEC/EN 60947-2, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-2-40 Annex JJ. It is also certified for isolation per IEC 60947-1 and has fire resistance to 960 °C per IEC 60695-2-11.

How is the GV2ME02TQ mounted?

It clips onto a 35 mm symmetrical DIN rail or can be panel-mounted with an adaptor plate. It can be mounted horizontally or vertically. Width is 45 mm (one modular space).