Schneider Electric GV2ME06A — Molded Case Circuit Breakers (MCCB)

Schneider Electric GV2ME06A TeSys Deca Motor Circuit Breaker

MPNGV2ME06A
Active

Schneider Electric TeSys Deca motor circuit breaker, GV2ME06A, 3-pole, thermal-magnetic, 1.6 A, 100 kA breaking capacity, dark grey.

$109.65Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME06A — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection
GV2ME06A — Mechanical
ParameterValue
Height4.0 in (101 mm)
Width1.8 in (45 mm)
Depth3.09 in (78.5 mm)
GV2ME06A — Electrical
ParameterValue
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2
GV2ME06A — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2ME
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2

Product details

Schneider Electric's GV2ME06A is a 3-pole thermal-magnetic motor circuit breaker from the TeSys Deca range, sized for a 1.6 A line rated current. Rated at 1.6 A, this little dark grey box handles motor starts up to 0.55 kW at 400 V or 1.1 kW at 690 V. Breaking capacity sits at 100 kA up to 690 V AC – that's a serious shortcut clearance for most industrial panels. You can often skip a separate fuse ahead of it. Rated for AC-3 and AC-3e duty, it's designed for the inrush of direct-on-line motors. Power dissipation is 2.5 W per pole – keep that in the enclosure calcs if you're stacking several.

Standards cover EN/IEC 60947-2 and -4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, plus glow-wire compliance per IEC/EN 60335. You've got the paperwork for global panels.

Frequently asked questions

What compliance documentation does Schneider provide for the GV2ME06A?

It is listed to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1, with additional glow-wire compliance per IEC/EN 60335.

MPN