The GV2ME06K1F7 is a non-reversing DOL combination starter from the TeSys GV2-ME range. It packages a 3-pole contactor, a motor circuit breaker (type GV2ME), and a combination block (GV2AF01) into a single unit, saving panel space and wiring time. The thermal protection adjustment range is 1 to 1.6 A, and the magnetic tripping current is fixed at 22.5 A. Rated for AC-3 utilization category (switching squirrel-cage motors), it handles motor loads up to 0.55 kW at 400/415 V AC and 0.75 kW at 500 V AC. The control circuit runs on 110 V AC 50/60 Hz.
The unit delivers a breaking capacity of 50 kA Iq at 400/415 V AC and 440 V AC, conforming to IEC 60947-4-1. This is a Type 1 coordination — meaning the starter is not expected to remain serviceable after a fault at that level, but it will safely clear the fault without damage to upstream gear. For a panel-builder, that 50 kA figure gives headroom on high-SCCR installations, but the Type 1 label means you plan for a replacement unit after a major short.
Sourcing reality — obsolete status
The GV2ME06K1F7 is marked obsolete by the manufacturer. If you're holding a plant-closure lot or a mixed pallet, this is one to sort and list with a clear lifecycle note: it's a known-good design, but the factory channel is closed.
Dimensions are 152 mm high, 45 mm wide, and 87 mm deep. That depth (87 mm) means it clears most standard 120 mm deep enclosures, but check the gland plate clearance if you're retrofitting into a shallow panel.
