Schneider Electric GV2ME06K1F7 — Miniature Circuit Breakers (MCB)

TeSys GV2ME06K1F7 DOL Starter, 1-1.6 A, 110 V AC, Obsolete

MPNGV2ME06K1F7
Obsolete

Schneider Electric TeSys GV2-ME series, GV2ME06K1F7, DOL combination starter, 1...1.6 A thermal protection range, 110 V AC 50/60 Hz control circuit voltage.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2ME06K1F7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME06K1F7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3
GV2ME06K1F7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME06K1F7 — Other specifications
ParameterValue
Motor power0.37 kW at 400/415 V AC 50/60 Hz 0.55 kW at 400/415 V AC 50/60 Hz 0.37 kW at 440 V AC 50/60 Hz 0.55 kW at 440 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 3-pole contactor 1 combination block GV2AF01 1 motor circuit breaker type GV2ME
Motor starter typeNon reversing
Magnetic tripping current22.5 A
Coil voltage110 V AC 50/60 Hz
Thermal protection adjustment range1...1.6 A

Product details

The GV2ME06K1F7 is a non-reversing DOL combination starter from the TeSys GV2-ME range. It packages a 3-pole contactor, a motor circuit breaker (type GV2ME), and a combination block (GV2AF01) into a single unit, saving panel space and wiring time. The thermal protection adjustment range is 1 to 1.6 A, and the magnetic tripping current is fixed at 22.5 A. Rated for AC-3 utilization category (switching squirrel-cage motors), it handles motor loads up to 0.55 kW at 400/415 V AC and 0.75 kW at 500 V AC. The control circuit runs on 110 V AC 50/60 Hz.

The unit delivers a breaking capacity of 50 kA Iq at 400/415 V AC and 440 V AC, conforming to IEC 60947-4-1. This is a Type 1 coordination — meaning the starter is not expected to remain serviceable after a fault at that level, but it will safely clear the fault without damage to upstream gear. For a panel-builder, that 50 kA figure gives headroom on high-SCCR installations, but the Type 1 label means you plan for a replacement unit after a major short.

Sourcing reality — obsolete status

The GV2ME06K1F7 is marked obsolete by the manufacturer. If you're holding a plant-closure lot or a mixed pallet, this is one to sort and list with a clear lifecycle note: it's a known-good design, but the factory channel is closed.

Dimensions are 152 mm high, 45 mm wide, and 87 mm deep. That depth (87 mm) means it clears most standard 120 mm deep enclosures, but check the gland plate clearance if you're retrofitting into a shallow panel.

Frequently asked questions

What is the thermal protection range of this starter?

The thermal protection adjustment range is 1 to 1.6 A. The fixed magnetic trip is set at 22.5 A.

What is the breaking capacity and coordination type?

It has a 50 kA breaking capacity at 400/415 V AC and 440 V AC, conforming to IEC 60947-4-1. The coordination type is Type 1.

What control voltage does this starter use?

The control circuit voltage is 110 V AC at 50/60 Hz.