Specifications

GV2ME06K1FE7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME06K1FE7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3
GV2ME06K1FE7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME06K1FE7 — Other specifications
ParameterValue
Motor power0.37 kW at 400/415 V AC 50/60 Hz 0.55 kW at 400/415 V AC 50/60 Hz 0.37 kW at 440 V AC 50/60 Hz 0.55 kW at 440 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 3-pole contactor 1 motor circuit breaker type GV2ME 1 combination block GV2AF01
Motor starter typeNon reversing
Magnetic tripping current22.5 A
Coil voltage115 V AC 50/60 Hz
Thermal protection adjustment range1...1.6 A

Product details

It integrates a 3-pole contactor, a GV2ME motor circuit breaker, and a GV2AF01 combination block into a single unit, saving panel space and wiring time compared to assembling those components separately. Rated for AC-3 utilization category, it's built for starting and stopping squirrel-cage induction motors under load. The thermal protection adjustment range of 1...1.6 A sets the overload trip point, so you match it to the motor's full-load current. The magnetic trip is fixed at 22.5 A, providing short-circuit protection coordinated with the thermal overload.

Motor power coverage

The GV2ME06K1FE7 covers motor power ratings from 0.37 kW up to 0.75 kW depending on the supply voltage. At 400/415 V it handles 0.37 kW or 0.55 kW; at 500 V it covers 0.37 kW, 0.55 kW, and 0.75 kW. That voltage-dependent power range is typical for IEC motor starters — the same thermal overload element works across a range of line voltages.

As a TeSys GV2-ME family member, it shares the same footprint and combination block interface as other ratings in the series. If your motor FLA changes, swapping to a different GV2ME thermal adjustment range is straightforward without re-paneling.

Physical integration

Dimensions are 152 mm height, 45 mm width, and 87 mm depth.