Schneider Electric GV2ME06K1U7 — Miniature Circuit Breakers (MCB)

Schneider GV2ME06K1U7 TeSys DOL Starter, 1-1.6 A, Obsolete

MPNGV2ME06K1U7
Obsolete

Schneider Electric TeSys GV2-ME DOL combination motor starter, GV2ME06K1U7, 1...1.6 A thermal protection, 230...240 V AC coil, 3-pole, non-reversing.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2ME06K1U7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME06K1U7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3
GV2ME06K1U7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME06K1U7 — Other specifications
ParameterValue
Motor power0.37 kW at 400/415 V AC 50/60 Hz 0.55 kW at 400/415 V AC 50/60 Hz 0.37 kW at 440 V AC 50/60 Hz 0.55 kW at 440 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 combination block GV2AF01 1 motor circuit breaker type GV2ME 1 3-pole contactor
Motor starter typeNon reversing
Magnetic tripping current22.5 A
Coil voltage230/240 V AC 50/60 Hz
Thermal protection adjustment range1...1.6 A

Product details

The Schneider Electric GV2ME06K1U7 is a TeSys GV2-ME direct-on-line (DOL) combination motor starter, integrating a 3-pole motor circuit breaker and a 3-pole contactor in one block, plus the GV2AF01 auxiliary contact block. It is rated for AC-3 duty with a thermal protection adjustment range of 1 to 1.6 A, making it suited for small motor loads in the 0.37 to 0.75 kW range depending on supply voltage.

The 1...1.6 A thermal protection range is the primary selection parameter — it sets the motor full-load current the overload relay will protect. For a 0.37 kW motor at 400/415 V AC, this range covers the expected FLC; the same starter also covers a 0.55 kW motor at 440 V or 0.75 kW at 500 V, per the rating table. Breaking capacity is 50 kA Iq at 400/415 V AC, conforming to IEC 60947-4-1. Coordination type is Type 1, meaning under a short-circuit fault the starter may require component replacement (contact tips may weld), but it will not cause a hazard.

Deployment Context

The non-reversing type is used for fixed-direction loads like pumps, fans, and conveyors where forward-only rotation is acceptable. For reversing applications, a separate reversing contactor assembly would be required.

Frequently asked questions

What is the thermal protection range of the GV2ME06K1U7?

The thermal protection adjustment range is 1 to 1.6 A, which sets the motor full-load current the overload relay protects.

What breaking capacity does the GV2ME06K1U7 offer?

It provides 50 kA breaking capacity at 400/415 V AC, conforming to IEC 60947-4-1.

What is the control circuit voltage for this starter?

The control circuit voltage is 230/240 V AC at 50/60 Hz.

What is the physical size of the GV2ME06K1U7?

It measures 45 mm wide, 152 mm high, and 87 mm deep.