Skip to main content
Schneider Electric GV2ME06K2B7 — Molded Case Circuit Breakers (MCCB)

Schneider GV2ME06K2B7 TeSys reversing motor starter, 1-1.6 A

MPNGV2ME06K2B7
Obsolete

Schneider Electric TeSys GV2-ME reversing combination motor starter, GV2ME06K2B7, 1...1.6 A thermal protection range, 24 V AC control, 50 kA breaking capacity.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME06K2B7 — Identification
ParameterValue
Product / component typeMotor starter
GV2ME06K2B7 — Mechanical
ParameterValue
Height152 mm
Width45 mm
Depth87 mm
GV2ME06K2B7 — Electrical
ParameterValue
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
GV2ME06K2B7 — Specifications
ParameterValue
Poles description3P
Device short nameGV2ME
GV2ME06K2B7 — Other specifications
ParameterValue
RangeTeSys
Motor power0.37 kW at 400/415 V AC 50/60 Hz 0.55 kW at 400/415 V AC 50/60 Hz 0.37 kW at 440 V AC 50/60 Hz 0.55 kW at 440 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device composition1 combination block GV2AF01 1 motor circuit breaker type GV2ME 1 3-pole reversing contactor
Motor starter typeReversing
Utilisation categoryAC-3
Magnetic tripping current22.5 A
Coil voltage24 V AC 50/60 Hz
Thermal protection adjustment range1...1.6 A

Product details

The GV2ME06K2B7 is a reversing DOL combination starter from the Schneider TeSys GV2-ME range. It integrates a motor circuit breaker, a 3-pole reversing contactor, and a GV2AF01 combination block into one unit, sized for a 1...1.6 A thermal protection adjustment range. Rated for AC-3 utilisation category, it handles motor loads up to 0.55 kW at 400/415 V AC and 0.75 kW at 500 V AC. The magnetic tripping current is set at 22.5 A, and the breaking capacity reaches 50 kA Iq at 400/415 V AC, certified to IEC 60947-4-1. Coordination type is Type 1, meaning the starter may need contactor replacement after a fault but the breaker self-protects.

The 24 V AC control coil suits installations where a control transformer supplies the contactor logic.

Frequently asked questions

What is the thermal protection adjustment range?

The thermal overload adjustment range is 1...1.6 A, set via the dial on the motor circuit breaker section.

What breaking capacity does it offer?

It provides 50 kA Iq at 400/415 V AC, 440 V AC, and 500 V AC, conforming to IEC 60947-4-1.

What control voltage does it require?

The control circuit voltage is 24 V AC at 50/60 Hz.

MPN
GV2ME06K2B7