Schneider Electric GV2ME07AP — Molded Case Circuit Breakers (MCCB)

Schneider GV2ME07AP TeSys Motor Circuit Breaker, 2.5 A, 100

MPNGV2ME07AP
Active

Schneider Electric TeSys Deca GV2ME07AP motor circuit breaker, 3-pole, 2.5 A rated current, thermal-magnetic trip, 100 kA breaking capacity at 400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME07AP — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection
GV2ME07AP — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth78.5 mm
GV2ME07AP — Electrical
ParameterValue
[In] rated current2.5 A
Breaking capacity100 kA Icu at 230/240 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2ME07AP — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2ME
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1

Product details

It's a 3-pole thermal-magnetic device with a rated current of 2.5 A, sized to protect a 0.75 kW motor at 400/415 V AC 50 Hz. It's phase-failure sensitive per IEC 60947-4-1, so it will trip if one phase drops out — a common cause of motor burnouts on lightly loaded lines.

In a panel with a transformer-fed supply capable of 65 kA fault current, this breaker still has headroom. Utilisation category AC-3 (IEC 60947-4-1) means it's rated for starting and stopping squirrel-cage motors — the standard duty for motor circuit breakers. AC-3e is the energy-efficient motor variant, same switching duty but tested with motors that draw higher inrush. Electrical durability is 100,000 cycles at 415 V at rated current for both AC-3 and AC-3e — that's a solid service life for a panel-mounted breaker. Dimensions are 89 mm high, 45 mm wide, 78.5 mm deep — a standard 45 mm module width that fits alongside contactors in a motor control centre. IP20 finger-safe protection on the front; IK04 impact resistance means it can take a knock from a dropped tool during panel servicing. Operating altitude is limited to 2000 m — above that, derate for air density.

Certified to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (contactor/motor-starter standard), plus UL 60947-4-1 and CSA C22.2 No 60947-4-1 for North American installations. Fire resistance rated at 960 °C per IEC 60695-2-11. Climatic withstand conforms to IACS for marine and offshore environments.

Frequently asked questions

What are the key ratings for the GV2ME07AP?

Rated current is 2.5 A, magnetic trip at 39 A, breaking capacity 100 kA Icu at 400/415 V AC. Motor power rating is 0.75 kW at 400/415 V AC 50 Hz. Rated operational voltage is 690 V AC. It is a 3-pole thermal-magnetic motor circuit breaker with phase-failure sensitivity.

What compliance documentation does Schneider provide for the GV2ME07AP?

The GV2ME07AP carries certifications to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. It also meets fire resistance at 960 °C per IEC 60695-2-11 and climatic withstand per IACS for marine environments.

What is the physical size of the GV2ME07AP?

Dimensions are 89 mm high, 45 mm wide, and 78.5 mm deep. It mounts on 35 mm symmetrical DIN rail or panel-mounts with an adaptor plate.