Schneider Electric GV2ME07K1Q7 — Miniature Circuit Breakers (MCB)

Schneider TeSys GV2ME07K1Q7 DOL Starter, 1.6-2.5 A, Obsolete

MPNGV2ME07K1Q7
Obsolete

Schneider Electric TeSys GV2-ME, DOL combination motor starter, GV2ME07K1Q7, 1.6...2.5 A thermal adjustment, 380...400 V AC control, 3-pole, non-reversing.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2ME07K1Q7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME07K1Q7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3
GV2ME07K1Q7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME07K1Q7 — Other specifications
ParameterValue
Motor power0.75 kW at 400/415 V AC 50/60 Hz 0.75 kW at 440 V AC 50/60 Hz 1.1 kW at 440 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 motor circuit breaker type GV2ME 1 combination block GV2AF01 1 3-pole contactor
Motor starter typeNon reversing
Magnetic tripping current33.5 A
Coil voltage380/400 V AC 50/60 Hz
Thermal protection adjustment range1.6...2.5 A

Product details

The Schneider Electric TeSys GV2ME07K1Q7 is a DOL (direct-on-line) combination motor starter, integrating a GV2ME motor circuit breaker, a GV2AF01 combination block, and a 3-pole contactor into one unit. The thermal protection adjustment range is 1.6...2.5 A, so it protects motors drawing full-load current in that band — set the dial to the motor nameplate FLA. The magnetic tripping current is fixed at 33.5 A, which clears short-circuit faults fast without nuisance trips on normal starting inrush.

Breaking capacity is 50 kA Iq at 400/415 V AC, conforming to IEC 60947-4-1. That 50 kA figure is the prospective short-circuit current the starter can safely interrupt under Type 1 coordination — after a fault the contactor may need replacement, but the breaker clears without rupturing. For a panel with high fault current (say, near a large transformer), this rating avoids cascading damage upstream. Motor power is 0.75 kW at 400/415 V AC, 0.75 kW at 440 V, and 1.1 kW at 500 V — match the motor voltage to the line voltage; the kW rating changes with voltage.

Where this class of part is used

This DOL combination starter is used in motor control panels for fixed-speed pumps, fans, compressors, and conveyors where reversing is not required. The integrated breaker and contactor save DIN-rail space and reduce wiring compared to separate components. The 45 mm width and 152 mm height fit standard enclosure layouts.

Frequently asked questions

What is the thermal protection adjustment range of the GV2ME07K1Q7?

The thermal protection adjustment range is 1.6...2.5 A. Set the dial to the motor nameplate full-load current within that band.

What is the breaking capacity of the GV2ME07K1Q7?

The breaking capacity is 50 kA Iq at 400/415 V AC, 440 V AC, and 500 V AC, conforming to IEC 60947-4-1 under Type 1 coordination.

What is the control circuit voltage for the GV2ME07K1Q7?

The control circuit voltage is 380/400 V AC 50/60 Hz. The coil is rated for that range.

MPN
GV2ME07K1Q7