Skip to main content
Schneider Electric GV2ME07K1U7 — Miniature Circuit Breakers (MCB)

Schneider TeSys GV2ME07K1U7 Motor Starter, 1.6-2.5 A, Obsole

MPNGV2ME07K1U7
Obsolete

Schneider Electric TeSys GV2-ME series, GV2ME07K1U7, DOL combination motor starter, 1.6...2.5 A thermal protection, 230...240 V AC control coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2ME07K1U7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME07K1U7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3
GV2ME07K1U7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME07K1U7 — Other specifications
ParameterValue
Motor power0.75 kW at 400/415 V AC 50/60 Hz 0.75 kW at 440 V AC 50/60 Hz 1.1 kW at 440 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 combination block GV2AF01 1 3-pole contactor 1 motor circuit breaker type GV2ME
Motor starter typeNon reversing
Magnetic tripping current33.5 A
Coil voltage230/240 V AC 50/60 Hz
Thermal protection adjustment range1.6...2.5 A

Product details

It is a non-reversing starter rated for AC-3 utilisation category, meaning it is built for starting and stopping squirrel-cage induction motors under load — the standard duty for conveyors, pumps, and fans in industrial control panels. The thermal protection adjustment range spans 1.6 to 2.5 A, so it is sized for small motors — for example, a 0.75 kW motor on a 400/415 V supply. The magnetic trip is fixed at 33.5 A, providing short-circuit protection that clears fast without nuisance tripping on normal inrush. Breaking capacity is 50 kA at 400/415 V AC, certified to IEC 60947-4-1. Coordination is Type 1, so after a fault the starter may need contact replacement, but the upstream protection stays intact.

The device composition includes one GV2AF01 combination block and a GV2ME motor circuit breaker, so if you are retrofitting an existing panel, verify the auxiliary block and contactor match the original assembly.

The 45 mm width occupies two 22.5 mm modular slots, so plan your enclosure fill factor accordingly. The depth of 87 mm includes the overhang of the coil terminals; leave clearance for wiring and a screwdriver above and below the block.

Frequently asked questions

What are the key ratings for this motor starter?

Thermal protection range is 1.6 to 2.5 A. Magnetic trip is fixed at 33.5 A. Breaking capacity is 50 kA at 400/415 V AC per IEC 60947-4-1. Control coil voltage is 230/240 V AC. It is rated for AC-3 duty, suitable for starting squirrel-cage motors up to 0.75 kW at 400/415 V or 1.1 kW at 500 V.

What is the physical size and mounting?

The GV2ME07K1U7 measures 45 mm wide, 152 mm high, and 87 mm deep. It snaps onto a standard DIN rail and occupies two 22.5 mm modular slots in the enclosure.

MPN
GV2ME07K1U7