Skip to main content
Schneider Electric GV2ME07K2F7 — Molded Case Circuit Breakers (MCCB)

Schneider GV2ME07K2F7 TeSys Reversing Starter, 1.6-2.5 A, 11

MPNGV2ME07K2F7
Obsolete

Schneider Electric TeSys GV2-ME series, reversing combination starter, GV2ME07K2F7, 1.6...2.5 A thermal protection, 110 V AC control coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME07K2F7 — Identification
ParameterValue
Product / component typeMotor starter
GV2ME07K2F7 — Mechanical
ParameterValue
Height152 mm
Width45 mm
Depth87 mm
GV2ME07K2F7 — Electrical
ParameterValue
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
GV2ME07K2F7 — Specifications
ParameterValue
Poles description3P
Device short nameGV2ME
GV2ME07K2F7 — Other specifications
ParameterValue
RangeTeSys
Motor power0.75 kW at 400/415 V AC 50/60 Hz 0.75 kW at 440 V AC 50/60 Hz 1.1 kW at 440 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device composition1 motor circuit breaker type GV2ME 1 3-pole reversing contactor 1 combination block GV2AF01
Motor starter typeReversing
Utilisation categoryAC-3
Magnetic tripping current33.5 A
Coil voltage110 V AC 50/60 Hz
Thermal protection adjustment range1.6...2.5 A

Product details

The Schneider GV2ME07K2F7 is a reversing DOL combination starter from the TeSys GV2-ME family. It integrates a 3-pole motor circuit breaker, a 3-pole reversing contactor, and a combination block (GV2AF01) into one DIN-rail-mounted assembly, saving panel space and wiring time on reversing motor circuits. Thermal protection adjusts from 1.6 to 2.5 A, and the magnetic trip is fixed at 33.5 A. The control coil runs on 110 V AC 50/60 Hz. Breaking capacity is 50 kA at 400/415 V, 440 V, and 500 V, certified to IEC 60947-4-1 with Type 1 coordination — meaning the starter can clear a fault up to that level, but the contactor may need replacement afterward. Rated motor power is 0.75 kW at 400/415 V and 440 V, and 1.1 kW at 500 V, all in AC-3 duty (squirrel-cage motor switching).

Frequently asked questions

What is the thermal adjustment range and what motor does it suit?

The thermal protection adjusts from 1.6 to 2.5 A. At 400/415 V AC, it is rated for 0.75 kW motors in AC-3 duty. At 500 V, the same thermal range supports 1.1 kW motors.

What is the breaking capacity of this starter?

It is rated for 50 kA at 400/415 V, 440 V, and 500 V AC, conforming to IEC 60947-4-1 with Type 1 coordination.

What control voltage does the coil require?

The control circuit voltage is 110 V AC at 50/60 Hz.

MPN