Skip to main content
Schneider Electric GV2ME07K2M7 — Miniature Circuit Breakers (MCB)

Schneider GV2ME07K2M7 TeSys Reversing Motor Starter, 1.6-2.5

MPNGV2ME07K2M7
Obsolete

Schneider Electric TeSys GV2-ME reversing DOL combination starter, GV2ME07K2M7, 1.6…2.5 A thermal protection, 220…230 V AC coil, 3-pole, 50 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2ME07K2M7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME07K2M7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3
GV2ME07K2M7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME07K2M7 — Other specifications
ParameterValue
Motor power0.75 kW at 400/415 V AC 50/60 Hz 0.75 kW at 440 V AC 50/60 Hz 1.1 kW at 440 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 combination block GV2AF01 1 3-pole reversing contactor 1 motor circuit breaker type GV2ME
Motor starter typeReversing
Magnetic tripping current33.5 A
Coil voltage220/230 V AC 50/60 Hz
Thermal protection adjustment range1.6...2.5 A

Product details

The Schneider Electric TeSys GV2ME07K2M7 is a reversing DOL combination starter — a single unit that integrates a motor circuit breaker (type GV2ME), a 3-pole reversing contactor, and a GV2AF01 auxiliary block. It's designed for direct-on-line reversing of three-phase induction motors up to 1.1 kW at 500 V AC. The thermal protection adjustment range is 1.6…2.5 A, and the magnetic trip is fixed at 33.5 A.

Breaking capacity is 50 kA at 400/415 V, 440 V, and 500 V AC, conforming to IEC 60947-4-1. Rated for AC-3 utilisation category (squirrel-cage motor starting, switching off during run). The motor power ratings are 0.75 kW at 400/415 V and 440 V, and 1.1 kW at 440 V and 500 V — so the same unit covers a 0.75 kW motor on a 400 V line or a 1.1 kW motor on a 500 V line, but the thermal setting must match the motor FLA. Coordination type is Type 1, meaning the starter may need contact replacement after a fault — acceptable for many industrial lines where downtime for replacement is planned, but not for processes that demand uninterrupted operation after a short-circuit.

Mounts on a DIN rail. Dimensions are 45 mm wide, 152 mm high, 87 mm deep — fits standard 45 mm modular enclosure slots.

This part is marked obsolete by the manufacturer.

Frequently asked questions

What is the closest alternative to GV2ME07K2M7 in the TeSys range?

No official successor order code is provided in the available records. A form-fit-function replacement would need to match the 1.6…2.5 A thermal range, 220/230 V AC coil, reversing function, and 50 kA breaking capacity — check the spec line yourself against current TeSys GV2ME or TeSys Deca catalogues.

MPN
GV2ME07K2M7