Skip to main content
Schneider Electric GV2ME08K1B7 — Miniature Circuit Breakers (MCB)

Schneider GV2ME08K1B7 TeSys DOL Motor Starter, 2.5-4 A, 24 V

MPNGV2ME08K1B7
Obsolete

Schneider Electric TeSys GV2-ME series, GV2ME08K1B7, DOL combination starter, thermal protection 2.5...4 A, 24 V AC 50/60 Hz control circuit, 50 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2ME08K1B7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME08K1B7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3
GV2ME08K1B7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME08K1B7 — Other specifications
ParameterValue
Motor power1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 motor circuit breaker type GV2ME 1 3-pole contactor 1 combination block GV2AF01
Motor starter typeNon reversing
Magnetic tripping current51 A
Coil voltage24 V AC 50/60 Hz
Thermal protection adjustment range2.5...4 A

Product details

The Schneider Electric GV2ME08K1B7 is a non-reversing DOL combination starter from the TeSys GV2-ME series, integrating a motor circuit breaker, a 3-pole contactor, and a combination block (GV2AF01) into one compact unit. It provides thermal and magnetic motor protection with an adjustable thermal range of 2.5...4 A and a fixed magnetic tripping current of 51 A, sized for AC-3 motor duty. The control circuit is rated for 24 V AC at 50/60 Hz, and the starter is rated for motor power up to 1.5 kW at 400/415 V AC and 2.2 kW at 500 V AC, making it suitable for small three-phase induction motors on pumps, conveyors, or fans in industrial control panels.

The 50 kA breaking capacity at 400/415 V AC, conforming to IEC 60947-4-1, means this starter can safely interrupt fault currents up to 50 kA without welding its contacts or cascading failure upstream — critical for installations with high available fault current, such as near a transformer secondary. The Type 1 coordination means that after a short-circuit fault, the contactor may need replacement, but the motor starter itself is protected. This is standard for most motor control centers where the contactor is a serviceable item.

Frequently asked questions

What replaces the GV2ME08K1B7?

No official successor order code is listed in the available records. A replacement would need to match the 2.5...4 A thermal protection range, 24 V AC control voltage, and 3-pole DOL configuration from the current TeSys GV2ME series or a comparable line.

What are the key ratings I need to match for a substitute?

The critical parameters are: adjustable thermal protection 2.5...4 A, fixed magnetic trip at 51 A, control voltage 24 V AC 50/60 Hz, 3-pole non-reversing DOL starter, and AC-3 utilisation category for motor duty.

MPN