Skip to main content
Schneider Electric GV2ME08K1M7 — Miniature Circuit Breakers (MCB)

GV2ME08K1M7 TeSys DOL Starter, 2.5-4 A, 220-230 VAC

MPNGV2ME08K1M7
Obsolete

Schneider Electric TeSys GV2-ME DOL combination starter, GV2ME08K1M7, 2.5...4 A thermal protection, 220...230 V AC 50/60 Hz control circuit, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2ME08K1M7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME08K1M7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3
GV2ME08K1M7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME08K1M7 — Other specifications
ParameterValue
Motor power1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 motor circuit breaker type GV2ME 1 3-pole contactor 1 combination block GV2AF01
Motor starter typeNon reversing
Magnetic tripping current51 A
Coil voltage220/230 V AC 50/60 Hz
Thermal protection adjustment range2.5...4 A

Product details

The GV2ME08K1M7 is a non-reversing DOL combination starter from the TeSys GV2-ME family, integrating a motor circuit breaker (2.5...4 A thermal protection adjustment range), a 3-pole contactor, and a combination block (GV2AF01) in a single 45 mm wide package. Rated for AC-3 utilisation category, it directly switches and protects three-phase induction motors up to 1.5 kW at 400/415 V AC or 2.2 kW at 500 V AC, with a magnetic tripping current of 51 A for short-circuit protection.

Breaking capacity is 50 kA Iq at 400/415 V, 440 V, and 500 V AC, conforming to IEC 60947-4-1. Coordination type is Type 1, so after a short-circuit the starter may require replacement of the contactor or breaker portion. For applications where uptime is critical, Type 2 coordination would be preferred, but this part is specified for Type 1 installations.

The only sourcing path for this exact order code is through the surplus and broker channel. A parametric replacement from the current TeSys range would need to match the 2.5...4 A thermal setting, 220/230 V AC coil, and 45 mm width — confirm fit by comparing the nameplate ratings on your existing starter.

Dimensions are 152 mm height, 45 mm width, and 87 mm depth — the 45 mm width is a standard 2-module DIN-rail footprint, so it occupies two 22.5 mm slots in the enclosure. Verify the 87 mm depth clears your enclosure door or cover when mounted.

Frequently asked questions

What is the closest alternative to the GV2ME08K1M7?

There is no official successor order code. A replacement would need to match the 2.5...4 A thermal protection range, 220/230 V AC coil, AC-3 motor rating, and 45 mm width — compare nameplate ratings against current TeSys GV2-ME or GV3P catalog numbers.

What is the breaking capacity of the GV2ME08K1M7?

50 kA at 400/415 V, 440 V, and 500 V AC, per IEC 60947-4-1. Coordination type is Type 1.

What motor power ratings does the GV2ME08K1M7 support?

Up to 1.5 kW at 400/415 V AC and 2.2 kW at 500 V AC, in AC-3 duty. The thermal protection range is 2.5...4 A.

How do I source this obsolete part?

Send an RFQ with your target quantity and acceptable condition (new, new-in-box, or used-tested). We search the independent surplus market and quote to order — no stock is held on the shelf.

MPN
GV2ME08K1M7