Schneider Electric GV2ME08K1P7 — Miniature Circuit Breakers (MCB)

Schneider GV2ME08K1P7 TeSys DOL Motor Starter, 2.5-4A

MPNGV2ME08K1P7
Active

Schneider Electric TeSys Deca Frame 2, GV2ME08K1P7, DOL combination starter, 2.5-4 A thermal adjustment, 230 V AC coil, 50 kA breaking capacity.

$139.70Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2ME08K1P7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME08K1P7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3 AC-3e
GV2ME08K1P7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME08K1P7 — Other specifications
ParameterValue
Motor power1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 3-pole contactor 1 motor circuit breaker type GV2ME 1 combination block GV2AF01
Motor starter typeNon reversing
Magnetic tripping current51 A
Coil voltage230 V AC 50/60 Hz
Thermal protection adjustment range2.5...4 A

Product details

The GV2ME08K1P7 is a non-reversing DOL combination starter from the TeSys Deca Frame 2 family. It integrates a GV2ME motor circuit breaker and a GV2AF01 combination block into a single 3-pole unit.

Rated breaking capacity is 50 kA Iq at 400/415 V, 440 V, and 500 V AC, conforming to IEC 60947-4-1. That 50 kA figure is the prospective fault current the device can safely interrupt — useful if your panel SCCR requirement is in that range. Coordination is Type 1, meaning after a fault the starter may need component replacement but the bus bars stay intact.

Motor power ratings across common voltages

Motor power depends on line voltage: 1.1 kW at 400/415 V, 1.5 kW at 440 V, and 2.2 kW at 500 V — all at 50/60 Hz. The 2.2 kW figure at 500 V is the highest rating in this adjustment range. If you're feeding a 400 V line, expect 1.1 kW maximum motor load.

Dimensions are 152 mm high, 45 mm wide, 87 mm deep. The combination block GV2AF01 is included, so the contactor and breaker are mechanically interlocked and pre-wired internally.

Frequently asked questions

What are the key ratings I need to check for fit?

Thermal protection adjustment range is 2.5-4 A — set this to match your motor's full-load amps. Control circuit voltage is 230 V AC 50/60 Hz. Breaking capacity is 50 kA at 400/415 V. Motor power rating is 1.1 kW at 400/415 V.

What is the magnetic trip current on this starter?

Magnetic tripping current is fixed at 51 A. This is the short-circuit protection threshold — above the thermal range, it clears high faults instantly.