Schneider Electric GV2ME08K1Q7 — Molded Case Circuit Breakers (MCCB)

Schneider Electric GV2ME08K1Q7 TeSys DOL Motor Starter, 2.5-

MPNGV2ME08K1Q7
Obsolete

Schneider Electric TeSys GV2-ME DOL combination starter, GV2ME08K1Q7, 2.5...4 A thermal protection, 380...400 V AC control circuit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME08K1Q7 — Identification
ParameterValue
Product / component typeMotor starter
GV2ME08K1Q7 — Mechanical
ParameterValue
Height152 mm
Width45 mm
Depth87 mm
GV2ME08K1Q7 — Electrical
ParameterValue
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
GV2ME08K1Q7 — Specifications
ParameterValue
Poles description3P
Device short nameGV2ME
GV2ME08K1Q7 — Other specifications
ParameterValue
RangeTeSys
Motor power1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device composition1 motor circuit breaker type GV2ME 1 combination block GV2AF01 1 3-pole contactor
Motor starter typeNon reversing
Utilisation categoryAC-3
Magnetic tripping current51 A
Coil voltage380/400 V AC 50/60 Hz
Thermal protection adjustment range2.5...4 A

Product details

The GV2ME08K1Q7 is a non-reversing DOL combination starter from the TeSys GV2-ME range, integrating a motor circuit breaker, a combination block GV2AF01, and a 3-pole contactor into one unit. It provides thermal protection adjustable from 2.5 to 4 A and magnetic tripping at 51 A, sized for motor loads up to 1.1 kW at 400/415 V AC or 1.5 kW at 500 V AC under AC-3 utilisation category. Rated breaking capacity is 50 kA Iq at 400/415 V AC conforming to IEC 60947-4-1, with Type 1 coordination, meaning the starter clears a fault up to that level without damage to the upstream protection but the contactor itself may need replacement after a short-circuit event.

Panel integration and fit

This is a standard TeSys GV2 footprint, so it fits existing panel layouts that use this series.

Frequently asked questions

What is the thermal protection adjustment range?

The thermal protection is adjustable from 2.5 to 4 A, set via the dial on the motor circuit breaker section of the combination starter.

What breaking capacity does this starter have?

It has a rated breaking capacity of 50 kA Iq at 400/415 V AC, 440 V AC, and 500 V AC, all conforming to IEC 60947-4-1 with Type 1 coordination.

What motor power can this starter handle?

It handles 1.1 kW at 400/415 V AC, 1.5 kW at 440 V AC, and up to 2.2 kW at 500 V AC, all under AC-3 duty for three-phase induction motors.

MPN
GV2ME08K1Q7