Schneider Electric GV2ME08K2B7 — Miniature Circuit Breakers (MCB)

Schneider GV2ME08K2B7 Reversing Starter, 2.5-4 A, 24 V AC

MPNGV2ME08K2B7
Active

Schneider Electric TeSys GV2-ME reversing combination motor starter, GV2ME08K2B7, 2.5...4 A thermal adjustment, 24 V AC 50/60 Hz coil, 3-pole, 50 kA breaking capacity at 400 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

GV2ME08K2B7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME08K2B7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3
GV2ME08K2B7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME08K2B7 — Other specifications
ParameterValue
Motor power1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 motor circuit breaker type GV2ME 1 3-pole reversing contactor 1 combination block GV2AF01
Motor starter typeReversing
Magnetic tripping current51 A
Coil voltage24 V AC 50/60 Hz
Thermal protection adjustment range2.5...4 A

Product details

The Schneider Electric GV2ME08K2B7 is a fully assembled reversing combination starter from the TeSys GV2-ME line. It integrates a GV2ME motor circuit breaker, a 3-pole reversing contactor pair, and a GV2AF01 mechanical interlock block into one DIN-rail-mountable unit. The thermal protection adjustment range is 2.5...4 A, and the control circuit runs on 24 V AC 50/60 Hz. This is a DOL (direct-on-line) reversing starter — it handles forward/reverse control of a three-phase motor without a separate reversing contactor assembly. The AC-3 utilization category means it is rated for switching squirrel-cage motors during starting, stopping, and reversing under load.

The thermal protection setting of 2.5...4 A governs the overload trip point. For a motor drawing its full-load current within that band, the bimetallic element tracks the heating curve. The magnetic trip is fixed at 51 A — that is the instantaneous short-circuit pickup, roughly 13× to 20× the thermal setting, which avoids nuisance tripping on motor inrush while still catching a phase-to-phase fault. Motor power ratings vary by supply voltage: 1.1 kW at 400/415 V, 1.5 kW at 440 V, and 2.2 kW at 500 V. On a 400 V line, this starter covers a 1.1 kW reversing motor load. The coordination type is Type 1 — meaning the starter itself may need replacement after a short-circuit fault, but the downstream contactor and the rest of the panel remain serviceable. Mechanical footprint: 45 mm wide, 152 mm tall, 87 mm deep. That is a standard three-module DIN-rail width.

Frequently asked questions

What are the key ratings I need to check for fit?

Thermal protection range is 2.5...4 A, magnetic trip is 51 A, control voltage is 24 V AC 50/60 Hz, and the breaking capacity is 50 kA at 400/415 V. Motor power is 1.1 kW at 400 V.

What is the physical size of this reversing starter?

Width 45 mm, height 152 mm, depth 87 mm. It mounts on standard DIN rail.

MPN