Schneider Electric GV2ME08K2F7 — Miniature Circuit Breakers (MCB)

Schneider GV2ME08K2F7 TeSys reversing motor starter, 2.5-4 A

MPNGV2ME08K2F7
Obsolete

Schneider Electric TeSys GV2-ME, DOL reversing combination starter, GV2ME08K2F7, 2.5...4 A, 110 V AC control.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2ME08K2F7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME08K2F7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3
GV2ME08K2F7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME08K2F7 — Other specifications
ParameterValue
Motor power1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 motor circuit breaker type GV2ME 1 combination block GV2AF01 1 3-pole reversing contactor
Motor starter typeReversing
Magnetic tripping current51 A
Coil voltage110 V AC 50/60 Hz
Thermal protection adjustment range2.5...4 A

Product details

The GV2ME08K2F7 is a DOL reversing combination starter from the TeSys GV2-ME range, integrating a GV2ME motor circuit breaker, a GV2AF01 combination block, and a 3-pole reversing contactor into a single assembly. Thermal protection adjusts from 2.5 to 4 A, and the control circuit runs on 110 V AC. This is a reversing starter — it handles forward/reverse motor control in one package, saving panel space over discrete components.

The 2.5...4 A thermal adjustment range sets the motor protection band — you set the dial to match your full-load current. This covers small three-phase motors in the 1.1 to 2.2 kW range at 400/415 V and 500 V supplies. Breaking capacity is 50 kA at 400/415 V and 500 V, certified to IEC 60947-4-1. That's high for a compact starter — it can interrupt a bolted fault up to 50 kA without upstream fuses or a bigger breaker, provided the coordination type (Type 1) is acceptable for your installation. Type 1 means the starter may not be serviceable after a fault; the contactor or breaker may need replacement. The magnetic trip is set at 51 A, which clears short-circuit conditions fast. The 3-pole design (3P) matches standard three-phase motor circuits. Dimensions are 45 mm wide, 152 mm high, 87 mm deep — a 45 mm footprint per pole, so it fits standard 45 mm-wide DIN-rail slots.

Frequently asked questions

What are the key ratings for this reversing starter?

Thermal protection adjustment range is 2.5...4 A. Breaking capacity is 50 kA at 400/415 V and 500 V AC, conforming to IEC 60947-4-1. Control voltage is 110 V AC 50/60 Hz. It is rated AC-3 for motor starting duty.

How do I source this obsolete part?

Submit an RFQ. We can search surplus and broker inventory for available units. Since there is no confirmed direct replacement, the RFQ should note the thermal range, control voltage, and reversing configuration so we can identify alternatives if stock is exhausted.

MPN
GV2ME08K2F7