Skip to main content
Schneider Electric GV2ME08K2U7 — Miniature Circuit Breakers (MCB)

Schneider GV2ME08K2U7 TeSys reversing starter, 2.5-4 A, obso

MPNGV2ME08K2U7
Obsolete

Schneider Electric TeSys GV2-ME series, DOL reversing combination starter, order code GV2ME08K2U7, thermal protection 2.5...4 A, control voltage 230/240 V AC 50/60 Hz, 50 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2ME08K2U7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2ME08K2U7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3
GV2ME08K2U7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm
GV2ME08K2U7 — Other specifications
ParameterValue
Motor power1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 3-pole reversing contactor 1 combination block GV2AF01 1 motor circuit breaker type GV2ME
Motor starter typeReversing
Magnetic tripping current51 A
Coil voltage230/240 V AC 50/60 Hz
Thermal protection adjustment range2.5...4 A

Product details

The GV2ME08K2U7 is a DOL reversing combination motor starter from the Schneider TeSys GV2-ME range. It integrates a 3-pole motor circuit breaker, a reversing contactor, and a combination block (GV2AF01) into a single unit, rated for AC-3 utilisation category — the standard for squirrel-cage motor switching. Thermal protection adjusts from 2.5 to 4 A, with a magnetic trip fixed at 51 A for short-circuit clearance.

Breaking capacity is 50 kA at 400/415 V AC conforming to IEC 60947-4-1 — that means this starter can safely interrupt a fault current up to 50 kA without welding its contacts or cascading damage upstream. The coordination type is Type 1, so after a short-circuit the starter may need contact replacement, but the breaker and contactor remain functional. Motor power ratings span 1.1 kW at 400 V through 2.2 kW at 500 V, which maps to a small pump, fan, or conveyor motor in a 400 V three-phase line. The 45 mm width (3-module DIN footprint) fits standard enclosure cutouts; overall dimensions are 152 mm high by 87 mm deep.

Frequently asked questions

What is the thermal protection range and magnetic trip setting?

The thermal adjustment range is 2.5 to 4 A. The magnetic short-circuit trip is fixed at 51 A, which provides instantaneous protection for motor starting inrush.

What breaking capacity does this starter have?

It is rated for 50 kA at 400/415 V AC, 440 V AC, and 500 V AC, all conforming to IEC 60947-4-1. This is a high-fault rating suitable for industrial distribution panels with high available short-circuit current.

What is the control voltage for this reversing starter?

The coil is rated for 230/240 V AC 50/60 Hz. This is a line-voltage coil, so it connects directly to the phase-to-neutral supply without a control transformer.

How do I source this obsolete part?

Submit an RFQ. We can locate GV2ME08K2U7 from surplus and broker channels — new-old-stock or verified used units. No stock or lead time is published; each request is quoted individually.

MPN
GV2ME08K2U7