Schneider Electric GV2ME10AE11TQ — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2ME10AE11TQ Motor Circuit Breaker, 6.3 A

MPNGV2ME10AE11TQ
Active

Schneider Electric TeSys GV2 motor circuit breaker, GV2ME10AE11TQ, 6.3 A rated, thermal-magnetic, 100 kA at 400 V, 3-pole, IP20, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME10AE11TQ — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection
GV2ME10AE11TQ — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth78.5 mm
GV2ME10AE11TQ — Electrical
ParameterValue
[In] rated current6.3 A
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage600 V AC 50/60 Hz conforming to UL 508 690 V AC 50/60 Hz conforming to IEC 60947-2 600 V AC 50/60 Hz conforming to CSA C22.2 No 14
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2ME10AE11TQ — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2ME
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2

Product details

It's sensitive to phase failure, so it will drop the motor if one phase is lost, which is standard for IEC 60947-4-1 compliance.

Rated IP20 open-mounted, so it's meant for inside an enclosure, not out in the weather. The screw-clamp terminals accept up to 6 mm² solid or 4 mm² flexible with ferrule, torqued to 1.7 N·m. Comes with 1 NO + 1 NC auxiliary contact built into the front, which saves you buying a separate block for basic status feedback.

Rated for the load

Motor power ratings: 2.2 kW at 400/415 V, 3 kW at 500 V, 4 kW at 690 V — all three-phase 50/60 Hz. The 6.3 A rated current covers a small motor, say a pump or a conveyor drive up to that kW range. Electrical durability is 100,000 cycles at rated current in AC-3 duty, mechanical durability also 100,000 cycles. That's solid for a manual motor starter in a machine that cycles a few times an hour. The 100 kA Icu at 400 V means you can put this on a panel with a high-fault-capacity transformer without worrying about the breaker failing to clear a dead short.

This is a current-production part — no end-of-life notice on it. It carries approvals under EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1, so it's accepted in North American and European panels. Also listed for IEC/EN 60335-2-40 (heat pump/air conditioner) and IEC/EN 60335-1 Clause 30.2 (glow-wire). Fire resistance is certified to 960 °C per IEC 60695-2-11.

Frequently asked questions

What are the key ratings I need to check for fit?

Rated current is 6.3 A, magnetic trip at 91 A. Motor power is 2.2 kW at 400 V, 3 kW at 500 V, 4 kW at 690 V. Breaking capacity is 100 kA at 400 V AC. It's a 3-pole thermal-magnetic breaker with phase-failure sensitivity.

What standards does this motor circuit breaker meet?

It complies with EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-2-40 Annex JJ. Fire resistance is 960 °C per IEC 60695-2-11.

MPN
GV2ME10AE11TQ