Schneider Electric GV2ME10K2BW3 — Miniature Circuit Breakers (MCB)

Schneider TeSys GV2ME10K2BW3 Motor Starter, 4-6.3 A, 24 VDC

MPNGV2ME10K2BW3
Active

Schneider Electric TeSys GV2-ME reversing combination starter, GV2ME10K2BW3, DOL, 4...6.3 A thermal adjustment, 24 V DC coil, 3-pole.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

GV2ME10K2BW3 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter

Ratings

GV2ME10K2BW3 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3

Mechanical

GV2ME10K2BW3 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm

Other specifications

GV2ME10K2BW3 — Other specifications
ParameterValue
Motor power2.2 kW at 400/415 V AC 50/60 Hz 2.2 kW at 440 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 combination block GV2AF01 1 3-pole reversing contactor 1 motor circuit breaker type GV2ME
Motor starter typeReversing
Magnetic tripping current78 A
Coil voltage24 V DC
Thermal protection adjustment range4...6.3 A

Product details

The Schneider TeSys GV2ME10K2BW3 is a DOL reversing combination motor starter — a single assembly that packs a motor circuit breaker, a reversing contactor, and the interlock into one 45 mm wide block. The thermal adjustment range is 4...6.3 A, covering small three-phase motors up to 2.2 kW at 400 V or 3 kW at 500 V. The 24 V DC coil keeps control voltage consistent across a 24 VDC control bus. Rated AC-3 (motor switching), it delivers 50 kA breaking capacity at 400/415 V and 500 V per IEC 60947-4-1. The magnetic trip is fixed at 78 A, so short-circuit response is fast and predictable.

Frequently asked questions

What is the thermal adjustment range and what motor does it cover?

The thermal protection adjusts from 4 to 6.3 A. It covers motors rated 2.2 kW at 400/415 V AC and up to 3 kW at 500 V AC.

What breaking capacity does it have?

It is rated for 50 kA at 400/415 V and 500 V AC, conforming to IEC 60947-4-1.

What is the control voltage?

The coil is 24 V DC.