Schneider Electric GV2ME10K2M7 — Molded Case Circuit Breakers (MCCB)

Schneider GV2ME10K2M7 TeSys DOL Reversing Starter, 4-6.3A

MPNGV2ME10K2M7
Obsolete

Schneider Electric TeSys GV2-ME DOL reversing combination motor starter, GV2ME10K2M7, thermal protection 4...6.3 A, 220...230 V AC control coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME10K2M7 — Identification
ParameterValue
Product / component typeMotor starter
GV2ME10K2M7 — Mechanical
ParameterValue
Height152 mm
Width45 mm
Depth87 mm
GV2ME10K2M7 — Electrical
ParameterValue
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
GV2ME10K2M7 — Specifications
ParameterValue
Poles description3P
Device short nameGV2ME
GV2ME10K2M7 — Other specifications
ParameterValue
RangeTeSys
Motor power2.2 kW at 400/415 V AC 50/60 Hz 2.2 kW at 440 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device composition1 combination block GV2AF01 1 motor circuit breaker type GV2ME 1 3-pole reversing contactor
Motor starter typeReversing
Utilisation categoryAC-3
Magnetic tripping current78 A
Coil voltage220/230 V AC 50/60 Hz
Thermal protection adjustment range4...6.3 A

Product details

The Schneider Electric TeSys GV2ME10K2M7 is a direct-on-line (DOL) reversing combination motor starter. It integrates a motor circuit breaker, a 3-pole reversing contactor, and a GV2AF01 auxiliary contact block into one DIN-rail-mountable unit. The thermal protection adjustment range is 4...6.3 A, and the control circuit voltage is 220/230 V AC 50/60 Hz. Rated for AC-3 utilization category, it delivers 2.2 kW at 400/415 V AC and up to 3 kW at 500 V AC. The magnetic tripping current is set at 78 A, providing short-circuit protection for the motor branch circuit.

The GV2ME10K2M7 offers a breaking capacity of 50 kA Iq at 400/415 V AC, 440 V AC, and 500 V AC, all conforming to IEC 60947-4-1. The coordination type is Type 1, meaning the starter may require component replacement after a fault, but the installation remains safe.

Panel footprint is 45 mm wide, 152 mm tall, and 87 mm deep. The 45 mm width occupies three standard 15 mm DIN-rail modules, leaving room for adjacent components in a crowded enclosure.

Frequently asked questions

What is the thermal protection adjustment range?

The thermal protection adjustment range is 4...6.3 A. This sets the overload trip threshold for the motor.

What is the breaking capacity of this motor starter?

The breaking capacity is 50 kA Iq at 400/415 V AC, 440 V AC, and 500 V AC, conforming to IEC 60947-4-1.

What control voltage does the GV2ME10K2M7 require?

The control circuit voltage is 220/230 V AC 50/60 Hz.

MPN