Schneider Electric GV2ME14K1V7 — Miniature Circuit Breakers (MCB)

Schneider Electric GV2ME14K1V7 TeSys Motor Starter, 6-10 A,

MPNGV2ME14K1V7
Obsolete

Schneider Electric TeSys GV2-ME series, GV2ME14K1V7, DOL combination motor starter, 6...10 A thermal protection, 400 V AC control voltage.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

GV2ME14K1V7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter

Ratings

GV2ME14K1V7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 15 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3

Mechanical

GV2ME14K1V7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm

Other specifications

GV2ME14K1V7 — Other specifications
ParameterValue
Motor power3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 combination block GV2AF01 1 3-pole contactor 1 motor circuit breaker type GV2ME
Motor starter typeNon reversing
Magnetic tripping current138 A
Coil voltage400 V AC 50/60 Hz
Thermal protection adjustment range6...10 A

Product details

The GV2ME14K1V7 is a non-reversing DOL combination motor starter from the TeSys GV2-ME range, integrating a 3-pole motor circuit breaker (type GV2ME) and a 3-pole contactor into one block with a GV2AF01 auxiliary contact block. The thermal protection adjustment range of 6 to 10 A sets the overload trip point for the connected motor. The magnetic trip is fixed at 138 A, which clears short-circuit faults without nuisance tripping on normal motor starting inrush. Coordination is Type 1, meaning after a fault the starter may need contact replacement but the enclosure and bus remain serviceable.

The GV2ME14K1V7 is obsolete.

Width of 45 mm on the DIN rail means it occupies a single modular slot in a standard enclosure. Height of 152 mm and depth of 87 mm are within the envelope of a typical motor control centre bucket or wall-mounted panel. The combination block format — breaker and contactor in one unit — reduces wiring compared to separate components. The GV2AF01 auxiliary block adds status feedback for the PLC or HMI.

Frequently asked questions

What is the thermal protection adjustment range?

The thermal overload adjustment range is 6 to 10 A, set via the dial on the breaker face.

What breaking capacity does it have?

It is rated for 50 kA at 400/415 V AC, 15 kA at 440 V AC, and 6 kA at 500 V AC, all per IEC 60947-4-1.

How do I source this obsolete part?

Since it is no longer manufactured, sourcing is through surplus or broker channels. Submit an RFQ for current availability and pricing.