Skip to main content
Schneider Electric GV2ME14K2M7 — Miniature Circuit Breakers (MCB)

Schneider GV2ME14K2M7 TeSys Reversing Motor Starter, 6-10 A

MPNGV2ME14K2M7
Active

Schneider Electric TeSys GV2-ME series, GV2ME14K2M7, DOL reversing combination motor starter, thermal protection 6...10 A, control circuit 220/230 V AC, 3-pole.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

GV2ME14K2M7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter

Ratings

GV2ME14K2M7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 15 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3

Mechanical

GV2ME14K2M7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm

Other specifications

GV2ME14K2M7 — Other specifications
ParameterValue
Motor power3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 3-pole reversing contactor 1 combination block GV2AF01 1 motor circuit breaker type GV2ME
Motor starter typeReversing
Magnetic tripping current138 A
Coil voltage220/230 V AC 50/60 Hz
Thermal protection adjustment range6...10 A

Product details

The Schneider Electric GV2ME14K2M7 is a DOL reversing combination motor starter from the TeSys GV2-ME range. It integrates a 3-pole motor circuit breaker with thermal and magnetic protection, a reversing contactor, and a GV2AF01 combination block into a single unit, so one order code covers the full reversing starter assembly for a panel. The thermal protection adjustment range is 6...10 A, which sets the overload trip point for the connected motor. The magnetic tripping current is fixed at 138 A, providing short-circuit protection that clears fast without waiting for the thermal element. Rated for AC-3 utilisation category, meaning it is designed for starting and stopping squirrel-cage induction motors under full load. The motor power ratings vary by supply voltage: 3 kW at 400/415 V AC, 4 kW at 440 V AC, and up to 5.5 kW at 500 V AC.

Breaking capacity is 50 kA at 400/415 V AC, 15 kA at 440 V AC, and 6 kA at 500 V AC, all conforming to IEC 60947-4-1. Coordination type is Type 1, so under a short-circuit fault the starter may require replacement of the contactor or breaker, but the installation is protected from fire or shock hazard. For applications where downtime must be minimised, a Type 2 coordinated assembly would be specified instead.

Control circuit and dimensions

Verify the control transformer or PLC output matches this voltage before wiring. Dimensions are 152 mm high, 45 mm wide, and 87 mm deep. The 45 mm width occupies three 15 mm DIN-rail module spaces, so plan enclosure fill accordingly.

Frequently asked questions

What are the key ratings for this motor starter?

Thermal protection adjustment range is 6...10 A, magnetic tripping current is 138 A, control voltage is 220/230 V AC, and breaking capacity is 50 kA at 400/415 V AC. Motor power rating is 3 kW at 400/415 V AC, up to 5.5 kW at 500 V AC.

What is the physical size of the GV2ME14K2M7?

Height is 152 mm, width is 45 mm (three DIN modules), and depth is 87 mm.

MPN
GV2ME14K2M7