Schneider Electric GV2ME14K2P7 — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2ME14K2P7 Motor Starter, 6-10 A, 230 V AC

MPNGV2ME14K2P7
Active

Schneider Electric TeSys GV2-ME series, DOL reversing combination starter, GV2ME14K2P7, thermal protection 6...10 A, 230 V AC control circuit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME14K2P7 — Identification
ParameterValue
Product / component typeMotor starter
GV2ME14K2P7 — Mechanical
ParameterValue
Height152 mm
Width45 mm
Depth87 mm
GV2ME14K2P7 — Electrical
ParameterValue
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 15 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
GV2ME14K2P7 — Specifications
ParameterValue
Poles description3P
Device short nameGV2ME
GV2ME14K2P7 — Other specifications
ParameterValue
RangeTeSys
Motor power3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device composition1 motor circuit breaker type GV2ME 1 combination block GV2AF01 1 3-pole reversing contactor
Motor starter typeReversing
Utilisation categoryAC-3
Magnetic tripping current138 A
Coil voltage230 V AC 50/60 Hz
Thermal protection adjustment range6...10 A

Product details

The GV2ME14K2P7 is a DOL reversing combination starter from the Schneider TeSys GV2-ME range. It integrates a motor circuit breaker, a combination block (GV2AF01), and a 3-pole reversing contactor into one unit, rated for AC-3 duty. The thermal protection adjustment spans 6...10 A, and the control circuit runs on 230 V AC 50/60 Hz.

The magnetic tripping current is set at 138 A, which handles the inrush of a motor within the thermal range without nuisance trips.

Coordination and integration notes

Coordination is Type 1 per IEC 60947-4-1, meaning the starter is protected against short circuits but may need contact replacement after a fault. The reversing contactor arrangement means two contactors are mechanically interlocked; verify the control wiring for direction interlocking before powering up.

Frequently asked questions

What are the key ratings for this motor starter?

Thermal protection adjustment range is 6...10 A, magnetic tripping current is 138 A, control voltage is 230 V AC, and breaking capacity is 50 kA at 400/415 V AC (IEC 60947-4-1). Motor power rating reaches 5.5 kW at 500 V AC.