Schneider Electric GV2ME14K2U7 — Molded Case Circuit Breakers (MCCB)

Schneider Electric GV2ME14K2U7 TeSys reversing motor starter

MPNGV2ME14K2U7
Active

Schneider Electric TeSys GV2-ME reversing DOL combination motor starter, GV2ME14K2U7, thermal adjustment 6...10 A, control voltage 230/240 V AC, breaking capacity 50 kA at 400 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME14K2U7 — Identification
ParameterValue
Product / component typeMotor starter
GV2ME14K2U7 — Mechanical
ParameterValue
Height152 mm
Width45 mm
Depth87 mm
GV2ME14K2U7 — Electrical
ParameterValue
Breaking capacity50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 15 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
GV2ME14K2U7 — Specifications
ParameterValue
Poles description3P
Device short nameGV2ME
GV2ME14K2U7 — Other specifications
ParameterValue
RangeTeSys
Motor power3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device composition1 motor circuit breaker type GV2ME 1 3-pole reversing contactor 1 combination block GV2AF01
Motor starter typeReversing
Utilisation categoryAC-3
Magnetic tripping current138 A
Coil voltage230/240 V AC 50/60 Hz
Thermal protection adjustment range6...10 A

Product details

The GV2ME14K2U7 is a reversing DOL combination motor starter from the TeSys GV2-ME range, integrating a 3-pole motor circuit breaker, a 3-pole reversing contactor, and a combination block into a single unit. It is sized for reversing motor loads up to 3 kW at 400/415 V AC or 5.5 kW at 500 V AC in AC-3 duty, with a thermal protection adjustment range of 6...10 A. The 230/240 V AC control circuit voltage matches standard European panel supplies, and the reversing contactor pair handles direction switching without external interlocking — the mechanical interlock is built into the combination block.

Breaking capacity and coordination — what the ratings mean

The breaking capacity is 50 kA Iq at 400/415 V AC, certified to IEC 60947-4-1. At 500 V AC the breaking capacity drops to 6 kA, so verify the fault level at the point of installation if running on a 500 V line. The magnetic tripping current is fixed at 138 A, which is roughly 13.8 times the upper thermal setting of 10 A. That gives a fast magnetic trip for short-circuit conditions while the thermal bimetal handles overloads in the 6...10 A adjustment range.

The combination block GV2AF01 is included, so the reversing contactor and breaker are mechanically interlocked and pre-wired — no additional bus bars or jumpers needed for the reversing function.

Frequently asked questions

What is the thermal protection adjustment range?

The thermal protection adjustment range is 6...10 A, set via the dial on the front of the motor circuit breaker section.

What breaking capacity does it offer at 400 V?

It offers 50 kA Iq at 400/415 V AC, certified to IEC 60947-4-1 under Type 1 coordination.

What is the control circuit voltage?

The control circuit voltage is 230/240 V AC, 50/60 Hz.