Schneider Electric GV2ME16A — Miniature Circuit Breakers (MCB)

Schneider GV2ME16A Motor Circuit Breaker, 14 A, 3-Pole

MPNGV2ME16A
Active

Schneider Electric TeSys Deca GV2ME16A motor circuit breaker, 3-pole, 14 A, thermal-magnetic trip, IP20 front face, dark grey.

$92.35Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

GV2ME16A — Identification
ParameterValue
Product nameTeSys GV2
Product rangeTeSys Deca
Product/component typeMotor circuit breaker
Device applicationMotor protection
GV2ME16A — Ratings
ParameterValue
Poles configuration3P
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 8 kA Icu 440 V AC 50/60 Hz IEC 60947-2 6 kA Icu 500 V AC 50/60 Hz IEC 60947-2 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz IEC 60947-2
Rated insulation voltage (Ui)690 V AC 50/60 Hz IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz IEC 60947-2
Utilisation categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1 AC-3e IEC 60947-4-1
GV2ME16A — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes IEC 60947-1
Electrical durability (cycles)100000 cycles AC-3 415 V In 100000 cycles AC-3e 415 V In
Mechanical durability (cycles)100000 cycles
GV2ME16A — Mechanical
ParameterValue
Control typePush-button
Terminal connection typePower circuit snap-in terminal 2 0.001...0.006 in² (0.75...4 mm²)solid Power circuit snap-in terminal 2 0.001...0.009 in² (0.75...6 mm²)flexible without cable end Power circuit snap-in terminal 2 0.001...0.006 in² (0.75...4 mm²)flexible with cable end
Width1.8 in (45 mm)
Height4.0 in (101 mm)
Depth3.09 in (78.5 mm)
GV2ME16A — Environmental
ParameterValue
Operating ambient temperature-4...140 °F (-20...60 °C)
Storage ambient temperature-40...176 °F (-40...80 °C)
IP degree of protectionIP20 IEC 60529 on front face)
GV2ME16A — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2
GV2ME16A — Electrical
ParameterValue
[Ics] rated service short-circuit breaking capacity100 % 230/240 V AC 50/60 Hz IEC 60947-2 50 % 400/415 V AC 50/60 Hz IEC 60947-2 50 % 440 V AC 50/60 Hz IEC 60947-2 75 % 500 V AC 50/60 Hz IEC 60947-2 75 % 690 V AC 50/60 Hz IEC 60947-2

Product details

The GV2ME16A is a 3-pole motor circuit breaker from Schneider's TeSys Deca range, rated 14 A line current with thermal-magnetic protection for motor overload and short-circuit isolation. It mounts on a 35 mm DIN rail or panel with an adaptor plate, occupies 45 mm width, and is suited for motor applications up to 5.5 kW at 400 V AC. Breaking capacity hits 100 kA Icu at 230/240 V AC (15 kA at 400 V), so it handles high fault levels common in industrial panels. Magnetic trip set at 253.4 A, and phase-failure sensitivity is included per IEC 60947-4-1. Rated uninterrupted duty, AC-3 utilisation category for motor switching. Electrical durability rated 100,000 cycles at 415 V under AC-3 and AC-3e conditions.

Listed to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (contactor-starter standard), plus UL 60947-4-1 and CSA C22.2 No 60947-4-1. Also meets IEC/EN 60335-2-40 Annex JJ and 60335-1 Clause 30.2 for fire resistance at 960 °C.

For a replacement or new design, this GV2ME16A is a common fast mover across MRO storerooms and OEM panels. The 14 A setting covers a range of motor sizes (5.5 kW at 400 V, 9 kW at 690 V). Power dissipation per pole is 2.5 W, so vertical stacking within an enclosure needs thermal derating consideration above 40 °C ambient. Connection uses snap-in terminals for 0.75–6 mm² flexible cable (without ferrules) or 0.75–4 mm² solid. IP20 on front face, IK04 impact resistance.

Frequently asked questions

What is GV2ME16A's listed color?

The device is dark grey.

What is GV2ME16A's depth?

Depth is 3.09 inches (78.5 mm).

What compliance documentation does this part carry?

The GV2ME16A is certified to IEC 60947-2, IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and meets fire resistance per IEC 60695-2-11 at 960 °C. It also satisfies IEC/EN 60335-2-40 Annex JJ and IEC/EN 60335-1 Clause 30.2.

MPN