GV2ME16A — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection
GV2ME16A — Mechanical
ParameterValue
Height4.0 in (101 mm)
Width1.8 in (45 mm)
Depth3.09 in (78.5 mm)
GV2ME16A — Electrical
ParameterValue
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 8 kA Icu 440 V AC 50/60 Hz IEC 60947-2 6 kA Icu 500 V AC 50/60 Hz IEC 60947-2 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2
GV2ME16A — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2ME
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2

Product details

The GV2ME16A is a 3-pole motor circuit breaker from Schneider's TeSys Deca range, rated 14 A line current with thermal-magnetic protection for motor overload and short-circuit isolation. It mounts on a 35 mm DIN rail or panel with an adaptor plate, occupies 45 mm width, and is suited for motor applications up to 5.5 kW at 400 V AC. Breaking capacity hits 100 kA Icu at 230/240 V AC (15 kA at 400 V), so it handles high fault levels common in industrial panels. Magnetic trip set at 253.4 A, and phase-failure sensitivity is included per IEC 60947-4-1. Rated uninterrupted duty, AC-3 utilisation category for motor switching. Electrical durability rated 100,000 cycles at 415 V under AC-3 and AC-3e conditions.

Listed to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (contactor-starter standard), plus UL 60947-4-1 and CSA C22.2 No 60947-4-1. Also meets IEC/EN 60335-2-40 Annex JJ and 60335-1 Clause 30.2 for fire resistance at 960 °C.

For a replacement or new design, this GV2ME16A is a common fast mover across MRO storerooms and OEM panels. The 14 A setting covers a range of motor sizes (5.5 kW at 400 V, 9 kW at 690 V). Power dissipation per pole is 2.5 W, so vertical stacking within an enclosure needs thermal derating consideration above 40 °C ambient. Connection uses snap-in terminals for 0.75–6 mm² flexible cable (without ferrules) or 0.75–4 mm² solid. IP20 on front face, IK04 impact resistance.

Frequently asked questions

What is GV2ME16A's listed color?

The device is dark grey.

What is GV2ME16A's depth?

Depth is 3.09 inches (78.5 mm).

What compliance documentation does this part carry?

The GV2ME16A is certified to IEC 60947-2, IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and meets fire resistance per IEC 60695-2-11 at 960 °C. It also satisfies IEC/EN 60335-2-40 Annex JJ and IEC/EN 60335-1 Clause 30.2.

MPN
GV2ME16A