Schneider Electric GV2ME16K1B7 — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2ME16K1B7 DOL Starter, 9-14A, 24V AC

MPNGV2ME16K1B7
Obsolete

Schneider Electric TeSys GV2-ME series, DOL combination starter GV2ME16K1B7, 9...14 A thermal protection, 24 V AC 50/60 Hz control voltage.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2ME16K1B7 — Identification
ParameterValue
Product / component typeMotor starter
GV2ME16K1B7 — Mechanical
ParameterValue
Height152 mm
Width45 mm
Depth87 mm
GV2ME16K1B7 — Electrical
ParameterValue
Breaking capacity15 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 8 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
GV2ME16K1B7 — Specifications
ParameterValue
Poles description3P
Device short nameGV2ME
GV2ME16K1B7 — Other specifications
ParameterValue
RangeTeSys
Motor power5.5 kW at 400/415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 7.5 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device composition1 3-pole contactor 1 combination block GV2AF01 1 motor circuit breaker type GV2ME
Motor starter typeNon reversing
Utilisation categoryAC-3
Magnetic tripping current170 A
Coil voltage24 V AC 50/60 Hz
Thermal protection adjustment range9...14 A

Product details

The GV2ME16K1B7 is a TeSys GV2-ME direct-on-line (DOL) combination starter from Schneider Electric, integrating a 3-pole motor circuit breaker and a contactor into a single non-reversing unit. It is designed for AC-3 duty — switching squirrel-cage motors — with a thermal protection adjustment range of 9 to 14 A and a control circuit voltage of 24 V AC 50/60 Hz. At 400/415 V AC, it delivers 5.5 kW motor power and carries a breaking capacity of 15 kA Iq per IEC 60947-4-1. At 500 V AC, the motor power rises to 7.5 kW, though the breaking capacity drops to 6 kA Iq. The magnetic tripping current is fixed at 170 A.

The 9...14 A thermal adjustment range sets the overload relay trip point for the motor full-load current — set it to the motor nameplate FLA. The 24 V AC control coil is standard for panel-level control transformers; verify the control circuit voltage matches your system before wiring. At 500 V, the 6 kA rating is the limiting figure for higher-voltage installations.

Integration notes

The composition includes a GV2AF01 combination block, so the breaker and contactor are mechanically interlocked and pre-wired internally.

Frequently asked questions

What are the key ratings for this starter?

Thermal protection range 9...14 A, control voltage 24 V AC 50/60 Hz, motor power 5.5 kW at 400/415 V AC, breaking capacity 15 kA at 400/415 V AC per IEC 60947-4-1.

How do I source this obsolete part?

It is sourced to order against an RFQ through independent distribution channels. Submit an RFQ for current availability and pricing.