Skip to main content
Schneider Electric GV2ME16K1BW3 — Miniature Circuit Breakers (MCB)

Schneider Electric GV2ME16K1BW3 TeSys DOL Starter, 9-14A, 24

MPNGV2ME16K1BW3
Obsolete

Schneider Electric TeSys GV2-ME, GV2ME16K1BW3, DOL non-reversing motor starter, 9...14 A thermal adjustment, 24 V DC coil.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

GV2ME16K1BW3 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter

Ratings

GV2ME16K1BW3 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity15 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 8 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3

Mechanical

GV2ME16K1BW3 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm

Other specifications

GV2ME16K1BW3 — Other specifications
ParameterValue
Motor power5.5 kW at 400/415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 7.5 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 3-pole contactor 1 motor circuit breaker type GV2ME 1 combination block GV2AF01
Motor starter typeNon reversing
Magnetic tripping current170 A
Coil voltage24 V DC
Thermal protection adjustment range9...14 A

Product details

The Schneider Electric GV2ME16K1BW3 is a direct-on-line (DOL) combination motor starter from the TeSys GV2-ME range. It bundles a 3-pole contactor, a GV2ME motor circuit breaker, and a GV2AF01 combination block into a single compact unit, saving panel space and wiring time. Rated for AC-3 duty (squirrel-cage motor switching), it handles 5.5 kW at 400/415 V and 7.5 kW at 500 V. The control coil is 24 V DC, so it plays well with PLC or safety-relay outputs without an extra transformer.

Breaking capacity hits 15 kA at 400/415 V per IEC 60947-4-1, dropping to 8 kA at 440 V and 6 kA at 500 V. That's a Type 1 coordination — meaning the starter survives the fault but may need contact replacement afterward. For a line-down call, that's acceptable if the alternative is a melted bus.

Frequently asked questions

What is the GV2ME16K1BW3's thermal protection range?

The thermal adjustment range is 9 to 14 A, set via the dial on the front of the motor circuit breaker section.

What control voltage does the GV2ME16K1BW3 use?

The control circuit voltage is 24 V DC.

What is the breaking capacity of the GV2ME16K1BW3?

It is rated 15 kA at 400/415 V AC, 8 kA at 440 V AC, and 6 kA at 500 V AC, all per IEC 60947-4-1.

How is the GV2ME16K1BW3 sourced given it is obsolete?

We source it to order through the independent surplus and broker channel. Submit an RFQ with your quantity and required lead time.

MPN
GV2ME16K1BW3