Schneider Electric GV2ME16K1M7 — Miniature Circuit Breakers (MCB)

Schneider Electric GV2ME16K1M7 TeSys DOL Starter, 9-14 A, 22

MPNGV2ME16K1M7
Obsolete

Schneider Electric TeSys GV2-ME, GV2ME16K1M7, DOL combination starter, 9...14 A, 220...230 V AC coil.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

GV2ME16K1M7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter

Ratings

GV2ME16K1M7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity15 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 8 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3

Mechanical

GV2ME16K1M7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm

Other specifications

GV2ME16K1M7 — Other specifications
ParameterValue
Motor power5.5 kW at 400/415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 7.5 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 combination block GV2AF01 1 3-pole contactor 1 motor circuit breaker type GV2ME
Motor starter typeNon reversing
Magnetic tripping current170 A
Coil voltage220/230 V AC 50/60 Hz
Thermal protection adjustment range9...14 A

Product details

Product Overview

It integrates a 3-pole motor circuit breaker and a 3-pole contactor into a single compact block, pre-wired and ready for panel mounting. The thermal protection adjustment range is 9...14 A, and the control circuit coil is rated for 220/230 V AC 50/60 Hz.

Rated for AC-3 utilization category, this starter handles the high inrush of squirrel-cage motors during starting. Motor power ratings reach 5.5 kW at 400/415 V AC and 7.5 kW at 500 V AC, so it's sized for common 3-phase induction motors in that power band. The magnetic tripping current is set at 170 A, providing short-circuit protection that coordinates with the thermal overload for Type 1 coordination. This is the rating that determines whether the starter can be used on a high-fault-capacity distribution board.

Integration Notes

The GV2ME16K1M7 is a non-reversing starter, so it's suited for fixed-speed applications like pumps, fans, and conveyors. The device composition includes the GV2AF01 combination block, the contactor, and the circuit breaker in one assembly, which simplifies panel wiring and reduces enclosure space compared to discrete components.

Frequently asked questions

What is the thermal protection adjustment range?

The thermal overload adjustment range is 9...14 A. This sets the motor full-load current at which the starter will trip on overload.

What control voltage does the coil require?

The control circuit coil is rated for 220/230 V AC at 50/60 Hz.

What is the breaking capacity of this starter?

The breaking capacity is 15 kA at 400/415 V AC, conforming to IEC 60947-4-1. It drops to 8 kA at 440 V AC and 6 kA at 500 V AC.

What motor power can this starter handle?

It is rated for 5.5 kW at 400/415 V AC and 440 V AC, and 7.5 kW at 500 V AC, all at 50/60 Hz.

MPN
GV2ME16K1M7