Schneider Electric GV2ME16K1P7 — Miniature Circuit Breakers (MCB)

Schneider Electric GV2ME16K1P7 TeSys DOL Starter, 9-14A, 230

MPNGV2ME16K1P7
Obsolete

Schneider Electric TeSys GV2-ME DOL combination starter, GV2ME16K1P7, 9...14 A thermal adjustment, 230 V AC coil, 3-pole non-reversing.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

GV2ME16K1P7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter

Ratings

GV2ME16K1P7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity15 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 8 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3

Mechanical

GV2ME16K1P7 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm

Other specifications

GV2ME16K1P7 — Other specifications
ParameterValue
Motor power5.5 kW at 400/415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 7.5 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 motor circuit breaker type GV2ME 1 combination block GV2AF01 1 3-pole contactor
Motor starter typeNon reversing
Magnetic tripping current170 A
Coil voltage230 V AC 50/60 Hz
Thermal protection adjustment range9...14 A

Product details

The GV2ME16K1P7 is a TeSys GV2-ME direct-on-line (DOL) combination starter from Schneider Electric. It integrates a motor circuit breaker (thermal-magnetic protection) with a 3-pole contactor in a single unit, pre-assembled with a combination block GV2AF01. The thermal protection adjustment range is 9...14 A, and the magnetic tripping current is fixed at 170 A. Rated for AC-3 utilisation category (squirrel-cage motor switching), it delivers motor power ratings of 5.5 kW at 400/415 V AC, 5.5 kW at 440 V AC, and 7.5 kW at 500 V AC, all at 50/60 Hz. The breaking capacity is 15 kA at 400/415 V, 8 kA at 440 V, and 6 kA at 500 V, conforming to IEC 60947-4-1.

The GV2ME16K1P7 measures 152 mm high, 45 mm wide, and 87 mm deep. The depth of 87 mm should be checked against enclosure clearance, especially if a contactor is mounted downstream or a combination block is fitted.

Frequently asked questions

What are the key ratings for this DOL starter?

Thermal protection adjustment range 9...14 A, magnetic tripping current 170 A, control voltage 230 V AC 50/60 Hz. Motor power: 5.5 kW at 400/415 V, 5.5 kW at 440 V, 7.5 kW at 500 V. Breaking capacity: 15 kA at 400/415 V, 8 kA at 440 V, 6 kA at 500 V (IEC 60947-4-1). AC-3 utilisation category.

What is the physical size of GV2ME16K1P7?

Height 152 mm, width 45 mm, depth 87 mm. The 45 mm width fits one standard DIN-rail slot.

MPN
GV2ME16K1P7