Schneider Electric GV2ME16K2BW3 — Miniature Circuit Breakers (MCB)

Schneider TeSys GV2ME16K2BW3 Reversing Motor Starter, 9-14 A

MPNGV2ME16K2BW3
Active

Schneider Electric TeSys GV2-ME series, reversing combination motor starter, GV2ME16K2BW3, 9...14 A thermal adjustment, 24 V DC coil, 3-pole.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

GV2ME16K2BW3 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter

Ratings

GV2ME16K2BW3 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity15 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 8 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 6 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1
Utilisation categoryAC-3

Mechanical

GV2ME16K2BW3 — Mechanical
ParameterValue
Width45 mm
Height152 mm
Depth87 mm

Other specifications

GV2ME16K2BW3 — Other specifications
ParameterValue
Motor power5.5 kW at 400/415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 7.5 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2ME
Device composition1 3-pole reversing contactor 1 combination block GV2AF01 1 motor circuit breaker type GV2ME
Motor starter typeReversing
Magnetic tripping current170 A
Coil voltage24 V DC
Thermal protection adjustment range9...14 A

Product details

The Schneider Electric GV2ME16K2BW3 is a DOL reversing combination starter from the TeSys GV2-ME series — a single assembly that integrates a 3-pole reversing contactor, a combination block (GV2AF01), and a motor circuit breaker (GV2ME) into one DIN-rail-mounted unit. The thermal protection adjustment range covers 9...14 A, and the control circuit runs on 24 V DC. It is rated for AC-3 duty (motor switching) and delivers 5.5 kW at 400/415 V AC, 5.5 kW at 440 V, and 7.5 kW at 500 V.

The AC-3 utilisation category tells you this starter is built for switching squirrel-cage motors — making and breaking stalled-rotor currents during starting, and handling the lower running current during normal operation. The 9...14 A thermal adjustment range sets the overload relay's trip threshold; you dial it to match the motor's full-load current. Magnetic tripping is fixed at 170 A, so short-circuit protection clears fast without waiting for the thermal element. Breaking capacity is 15 kA at 400/415 V AC per IEC 60947-4-1, dropping to 8 kA at 440 V and 6 kA at 500 V. Coordination is Type 1 — after a fault the starter may need component replacement, but the breaker clears the fault without welding main contacts. This is standard for panel designs where downstream protection is sized to limit let-through energy.

This is a reversing starter — two contactors mechanically and electrically interlocked to swap two phases for motor reversal. The 24 V DC coil is common in PLC-controlled lines where the control voltage matches the I/O rack supply. No separate overload relay or contactor assembly to wire — the combination block handles the interlock and power bus.

Frequently asked questions

What is the thermal protection adjustment range?

The thermal overload adjustment range is 9...14 A, set via the dial on the front of the motor circuit breaker section.

What control voltage does the coil require?

The control circuit voltage is 24 V DC.

What motor power can this starter handle?

It is rated for 5.5 kW at 400/415 V AC and at 440 V AC, and 7.5 kW at 500 V AC, all at 50/60 Hz.

What is the breaking capacity?

Breaking capacity is 15 kA at 400/415 V AC, 8 kA at 440 V AC, and 6 kA at 500 V AC, per IEC 60947-4-1.