Schneider Electric GV3P181 — Miniature Circuit Breakers (MCB)

GV3P181 TeSys Deca Motor Circuit Breaker, 18 A, 100 kA

MPNGV3P181
Obsolete

Schneider Electric TeSys Deca GV3P181, motor circuit breaker, 3-pole, 18 A rated current, thermal-magnetic, 100 kA breaking capacity at 400 V AC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV3P181 — Identification
ParameterValue
Product nameTeSys GV3
Product rangeTeSys Deca
Product/component typeMotor circuit breaker
Device applicationMotor protection
GV3P181 — Ratings
ParameterValue
Rated current (In)18 A
Poles configuration3P
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage (Ui)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz conforming to IEC 60947-2
Utilisation categoryCategory A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1
GV3P181 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to IEC 60947-1
Electrical durability (cycles)50000 cycles for AC-3 at 415 V In
Mechanical durability (cycles)50000 cycles
GV3P181 — Mechanical
ParameterValue
Control typeRotary handle
Terminal tightening torque5 N.m - on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
GV3P181 — Environmental
ParameterValue
Operating ambient temperature-20...60 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
GV3P181 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-1:Clause 30.2 IEC/EN 60335-2-40:Annex JJ
GV3P181 — Electrical
ParameterValue
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2

Product details

The GV3P181 is a 3-pole motor circuit breaker from the TeSys Deca range, rated 18 A continuous with a thermal-magnetic trip unit. The thermal adjustment range spans 12 to 18 A, so you set it to match the motor full-load amperage within that window. That rating holds the unit on the grid for high-fault installations. At 690 V the Icu drops to 6 kA, which still covers most motor branch circuits at that voltage level. Phase failure sensitivity is built in per IEC 60947-4-1, so a lost phase on the line side will trip the breaker before the motor single-phases to destruction.

The 55 mm width means it occupies three standard 18 mm module positions on the rail. Depth is 136 mm, which clears most 150 mm deep enclosures, but check gland-plate clearance if the rotary handle protrudes through the door. IP20 finger-safe terminals are fine inside a locked cabinet; the enclosure itself carries IK09 impact rating. Mounting position can be horizontal or vertical with no derating, which simplifies layout in crowded panels. The rotary handle is the control type, so a door interlock or handle extension may be needed for external operation depending on enclosure design.

Compliant with EN/IEC 60947-2 (circuit-breaker standard), EN/IEC 60947-4-1 (contactor/motor-starter standard), UL 60947-4-1, and CSA C22.2 No 60947-4-1. Also tested to IEC/EN 60335-1 Clause 30.2 and IEC/EN 60335-2-40 Annex JJ for glow-wire and fire resistance at 960 °C. Climatic withstand per IACS covers marine and humid environments.

Durability and thermal management

Electrical durability is 50,000 cycles at AC-3 duty at 415 V at full rated current. Mechanical durability matches at 50,000 cycles. Power dissipation is 8 W per pole, so at 18 A load the three poles together dissipate 24 W inside the enclosure. In a sealed box with multiple breakers, that heat adds up and may require derating or ventilation above 40 °C ambient. Shock rating is 15 Gn for 11 ms with the contactor open, 30 Gn closed. Vibration withstand is 4 Gn from 5 to 300 Hz.

Frequently asked questions

What is the closest alternative to the GV3P181 in the same family?

Within the TeSys Deca GV3P series, the closest alternative is a different current rating. The GV3P181 is the 18 A variant with a 12–18 A thermal adjustment range. If your motor FLA falls outside that window, the GV3P series offers other ratings at 55 mm width and the same breaking capacity. There is no pin-compatible drop-in with a different rating; the thermal-magnetic trip assembly is integral to the unit.

What compliance documentation is available for the GV3P181?

The GV3P181 carries compliance to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-1 Clause 30.2 and IEC/EN 60335-2-40 Annex JJ. Climatic withstand is per IACS. RoHS and REACH declarations are standard from the manufacturer for this range.

What is the depth of the GV3P181?

The GV3P181 has a depth of 136 mm, a width of 55 mm, and a height of 132 mm. The 136 mm depth includes the body and the rotary handle; clearance for handle swing and wiring should be verified in shallow enclosures.

MPN
GV3P181