Schneider Electric ILT2V573MC0A
MPNILT2V573MC0A
Obsolete
integrated drive ILT with stepper motor - 24..48V DC - Pulse/Direction - 1.44N.m
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Motor type | 2-phase stepper motor |
| Network type | DC |
| Winding type | Medium speed of rotation and medium torque |
| Feedback type | Without |
| Gear box type | Without |
| Protection type | Overload of output voltage Short circuit of the output voltage |
| Range of product | Lexium integrated drive |
| Input (output type) | 3 inputs (Step Clock, Direction, Enable) |
| Product or component type | Motion integrated drive |
| Supply voltage limits | 12...48 V |
| Supply voltage | 24...48 V |
| Voltage state 1 guaranteed | >= 2.2 V |
All specifications
| Parameter | Value |
|---|---|
| Current consumption | 3.2 A maximum continuous |
| IP degree of protection | IP41 shaft bushing: conforming to EN/IEC 60034-5 IP54 total except shaft bushing: conforming to EN/IEC 60034-5 |
| Communication interface | Pulse/Direction 5 -24 V |
| Mounting support | Flange |
| Electrical connection | Industrial connector |
| Relative humidity | 15...85 % without condensation |
| Operating altitude | <= 1000 m without derating |
| Standards | EN 61000-3-2 : 2006 IEC 61000-4-5 IEC 61000-4-6 EN 55011:2007, A2:2007 for Group 1, Class A EMC immunity IEC 61000-4-2 IEC 61000-4-11 IEC 61000-4-4 EN 61000-3-3:1995, A1:2001, A2:2005 IEC 61000-4-3 |
| Length | 118.62 mm |
| Marking | CE |
| Holding brake | Without |
| Nominal speed | 300 rpm at 24 V 450 rpm at 48 V |
| Rotor inertia | 0.46 kg.cm² |
| Accuracy error | +/- 0.3 arc/min |
| Holding torque | 1.44 N.m |
| Device short name | ILT |
| Motor flange size | 57 mm |
| Peak stall torque | 1.44 N.m |
| Service life in hours | 20000 h |
| Continuous stall torque | 1.44 N.m |
| Speed feedback resolution | 1000 steps 10000 steps 12800 steps 1600 steps 200 steps 2000 steps 20000 steps 25000 steps 25600 steps 3200 steps 400 steps 40000 steps 5000 steps 50000 steps 51200 steps 6400 steps 800 steps |
| Ambient air temperature for storage | -25...70 °C |
| Ambient air temperature for operation | 50...65 °C (with power derating of 2 % per °C) 0...50 °C (without derating) |
| Permissible ambient air temperature around the device | 100 °C |
MPN
ILT2V573MC0A