Schneider Electric LC1D50ND — Contactors

Schneider Electric LC1D50ND

MPNLC1D50ND
Obsolete

contactor TeSys Deca - 3 poles - AC-3 440V 50 A - coil 60 V DC

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1D50ND — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LC1D50ND — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-4 AC-3 AC-2 AC-1
LC1D50ND — Contacts & Poles
ParameterValue
Pole configuration3P
LC1D50ND — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529 IP2X conforming to VDE 0106
Operating altitude0...3000 m
Mechanical robustnessShocks contactor opened (10 Gn for 11 ms) Shocks contactor closed (15 Gn for 11 ms) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
LC1D50ND — Approvals
ParameterValue
StandardsIEC 60947-5-1 CSA C22.2 No 14 EN 60947-4-1 IEC 60947-4-1 EN 60947-5-1 UL 508
LC1D50ND — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth176 mm
MPN
LC1D50ND