Schneider Electric LC1E06004M5WBIN — Contactors

Schneider LC1E06004M5WBIN Easy TeSys Contactor, 20 A AC-1, 2

MPNLC1E06004M5WBIN
Active

Schneider Electric Easy TeSys Control, contactor LC1E06004M5WBIN, 4 NO poles, 20 A AC-1 at ≤415 V, 220 V AC 50 Hz coil, screw clamp terminals, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E06004M5WBIN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E06004M5WBIN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC1E06004M5WBIN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E06004M5WBIN — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E06004M5WBIN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E06004M5WBIN — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The LC1E06004M5WBIN: AC-1 is the resistive-load curve — this contactor is not rated for motor starting (AC-3) or inductive switching. The 20 A rating at ≤415 V is the operational current for that duty; the rated breaking capacity is 48 A at 440 V, and the making capacity hits 60 A at 440 V AC per IEC 60947-4-1. Electrical durability is 150,000 cycles under AC-1, with mechanical durability at 10 million cycles — a solid figure for a panel that cycles a few times per hour. The 4 NO pole configuration with no auxiliary contacts means you'll need a separate contactor or relay block for feedback signals. Control circuit screw-clamp terminals accept 1 to 4 mm² flexible with cable end, or up to 6 mm² solid. The 80 mm depth, 45 mm width, and 74 mm height fit standard DIN-rail or plate mounting — no surprises for panel layout.

Protective treatment TH per IEC 60068 means it's tested for tropical humidity — no extra coating needed for damp environments. Active lifecycle status means it's a current catalog item, not a phase-out.

Sourcing and integration

The 12 A gG fuse coordination type 1 at ≤690 V is specified for the power circuit; use that as the upstream protection limit.

Frequently asked questions

What are the key ratings for this contactor?

Rated operational current 20 A in AC-1 at ≤415 V, control circuit voltage 220 V AC 50 Hz, 4 NO poles, rated insulation voltage 690 V, and electrical durability 150,000 cycles under AC-1.

MPN
LC1E06004M5WBIN